www.perkinelmer.
ordering information New Investments – Local Support – Proven Quality! For over 50 years, PerkinElmer has helped our global laboratory partners meet their most demanding application measurement challenges. Our experience in Chromatography, Spectroscopy and Material Characterization gives us a unique advantage in providing holistic and comprehensive solutions for laboratories in universities and key market segments like Environmental, Energy, and Food & Product Safety.
Order Online Table of Contents Atomic Absorption Place your order online at: www.perkinelmer.com/supplies Online ordering is currently available in Australia, Austria, Belgium, Canada, Denmark, Finland, France, Germany, Ireland, Italy, Luxemburg, the Netherlands, Norway, Puerto Rico, Spain, Sweden, Switzerland, the United Kingdom and the United States. Order by Phone, Fax or E-mail HCL and EDL Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–9 Burner System Components . . . . . . . . . . .
NEW! PerkinElmer Atomax 1.5 Inch Hollow High quality 1.5" Lamps designed for any Atomic Absorption Instrument Features and Benefits ■ Experts: Expertise designing and manufacturing quality lamps for over 40 years. A brand you can trust. ■ Compatibility: Compatible with other manufacturer’s instruments — tested and approved. ■ Lifetime: Long lifetime and performance.
Cathode Lamps PerkinElmer offers a complete selection of Atomax 1.5" Single-Element Atomic Absorption Lamps PerkinElmer Exclusive 6/24 Warranty* Atomax™ Hollow Cathode Lamps 1. We warrant that during the first six months or after 5,000 milliampere-hours of operation, whichever comes first, from initial date of shipment, the lamps will meet or exceed the intensity and absorption specifications to which all new lamps are tested. 2.
Genuine PerkinElmer Lumina ™ Hollow PerkinElmer has 40 years of expertise designing and manufacturing Hollow Cathode Lamps Every genuine PerkinElmer Lumina Lamp is designed for use with and tested on, our spectrometers to assure compatibility and the highest performance To prolong the life of a Lumina Hollow Cathode Lamp (HCL), we produce lamps with larger internal volume so that a greater supply of fill gas at optimum pressure is available.
Cathode Lamps for Atomic Absorption Small Diameter Lamp Adapter Kit Permits the use of small diameter 8-pin hollow cathode lamps. Part No. N3051050 PerkinElmer Exclusive 6/24 WARRANTY* Lumina™ Hollow Cathode Lamps 1. We warrant that during the first six months or after 5,000 milliampere-hours of operation, whichever comes first, from initial date of shipment, the lamps will meet or exceed the intensity and absorption specifications to which all new lamps are tested. SPECIAL SAVINGS OFFERS 2.
System 2 Electrodeless Discharge Lamps Electrodeless Discharge Lamps are an ideal source for determining volatile elements EDLs provide greater light output and longer life than corresponding HCLs For certain elements such as Arsenic and Selenium, EDLs will also provide improved sensitivity and lower detection limits. System 2 electrodeless discharge lamps provide the optimized spectral output needed to get the maximum performance from PerkinElmer atomic absorption spectrometers.
Maximum Intensity and Long Life Features and Benefits ■ Brightness: EDLs are much brighter and, in some cases, provide better sensitivity than comparable hollow cathode lamps ■ Precision: EDLs offer lower detection limits and are preferred for analyses that are “noisy” due to weak hollow cathode emission ■ Long Life: System 2 EDLs are long-lived for exceptional cost-effectiveness ■ Automation: PerkinElmer coded lamps allow automatic set-up on systems with automated turret ■ Quality: Carefully sele
Burner System Components for Optimal PerkinElmer offers a full range of replacement burner heads and mixing chambers Burner Heads There are four burner heads available for use with the burner system. They are all made of solid titanium, which is corrosion resistant and free of most of the elements commonly determined by atomic absorption. Single-slot Nitrous Oxide-acetylene 5 cm The 5 cm nitrous oxide burner head is required for nitrous oxide-acetylene operation.
Efficiency A D Burner System Components E A Burner Head D Flow Spoiler B Burner Mixing Chamber E End Cap O-ring C Clamping Ring F End Cap Assembly C F B For our complete listing of Burner System Components, please visit: www.perkinelmer.com/aasupplies Burner System Components Burner Heads For AAnalyst 50/100/200/300/400/700/800 For 2280, 2380, 3030(B), 3100, 3110, 3300, 4000, 5000, 5100PC For 1100(B), 2100, 4100 Description Length Flame Type Part No. Part No. Part No.
PerkinElmer High-Performance Nebulizers PerkinElmer nebulizers are available in a variety of configurations to meet all of your analytical needs The nebulizer is one of the most important components in a flame AA spectrometer Sample solutions, with differing physical properties, must be converted into an aerosol of small, similarly-sized droplets. This places great demands on the design of the nebulizer.
for Flame AA Corrosion-Resistant Nebulizers Platinum Alloy Nebulizers ■ For all solutions containing hydrofluoric acid or aqua regia ■ Recommended for most concentrated acids containing >5% acid ■ For all solutions containing high concentrations of dissolved solids ■ Includes a platinum alloy needle assembly and a tantalum venturi All internal components in contact with solutions are constructed of plastic to resist corrosion from concentrated acids ■ Provides maximum chemical resistance ■ No
nebulizer components PerkinElmer offers a full selection of parts for your nebulizer GemTip™ Nebulizer Plastic Body Nebulizers High-Sensitivity Nebulizer with Pt/Ir Capillary1 For AAnalyst 50/200/400 For AAnalyst 100/300/700/800, 5100 PC, 5000, 3300, 3100 For 4100, 2100, 1100(B) Description Part No. Part No. Part No.
148-Position Tray 88-Position Tray Autosampler Trays Special Savings offers from PerkinElmer! Save when you purchase a For a quick change to another series of samples, a second sample tray is recommended. For Model AS-800 Description Part No. 88-Position Tray, Polypropylene 80 sample locations for 2.0, 2.5 or 3.5 mL sample cups. Each sample tray also has eight positions for 7.0 mL reagent containers. 148-Position Tray, Polypropylene 132 sample locations for 1.
Trust your Analysis to Genuine PerkinElmer Rely on PerkinElmer graphite for consistent analytical results. Every sample. Every day. Our pyrolytic coating design is critical to achieving high performance The specified thickness of pyrolytic coating applied to PerkinElmer graphite improves the total resistance of the graphite tube and the temperature distribution within the tube. Improper pyrolytic coating can shorten tube lifetime dramatically.
Graphite Do not accept imitations Graphite components offered by other companies often refer to the PerkinElmer part, implying that these components are made from the same material and provide equivalent performance. This is misleading, as these imitation components are not made from the same base graphite material, nor are they tested to the same demanding quality control specifications.
HGA Pyrocoated Graphite Tubes and L’vov We have put 30 years of expertise into the development of our graphite tubes, contact cylinders and platforms PerkinElmer tubes are manufactured to the highest quality specifications The production of high-quality graphite components requires stringent quality control. To ensure high quality and consistency, a specific grade of high-density base graphite material has been developed for PerkinElmer’s exclusive use.
Platforms SPECIAL SAVINGS OFFERS from PerkinElmer! Save on HGA Graphite Tube 20-packs! Please contact your local sales office for more details. Delivering Enhanced Value and Outstanding Savings on the products you use most! L’vov Platforms The L’vov platform is a small plate of solid pyrocoated graphite that is inserted into the graphite tube. It has a slight depression in the center, which can accommodate up to 50 μL of solution.
THGA Graphite Tubes Only Available from Our exclusive design ensures even heating over the entire length of the tube Standard THGA Graphite Tubes Today’s analysts expect exceptional analytical performance from their graphite furnace atomic absorption spectrometers. That performance must be reproducible from day to day with respect to sensitivity (characteristic mass), accuracy and precision. The graphite tube, the heart of the graphite furnace, plays a vital role in the overall stability of an analysis.
PerkinElmer THGA Contact Cylinders These graphite contact cylinders are engineered for a precise fit so that variations in electrical contact –– which might affect the analytical performance — are reduced to a minimum. Contact cylinders with a modified injection port area help to minimize condensation and improve analytical performance with difficult matrices. Standard THGA Graphite Contact Cylinders Description Part No.
nebulizers Concentric Nebulizers offer high-quality sample introduction for a wide variety of applications MicroMist Nebulizers The MicroMist micro-uptake glass concentric nebulizer offers high performance for limited sample volumes. MicroMists with sample uptakes 0.2 – 0.6 mL/min are fitted with a UniFit connector with 1.3 mm o.d. x 0.50 mm i.d. x 700 mm long sample tubing. MicroMists with sample uptakes 0.05 – 0.1 mL/min are fitted a UniFit connector with 1.3 mm o.d. x 0.25 mm i.d.
nebulizers GemCone and GemTip Nebulizers only from PerkinElmer GemTip Cross-Flow II Nebulizers Excellent general purpose nebulizer for the analysis of strong mineral acids (including HF) and samples with less than 5% dissolved solids. It can routinely handle 50% (v/v) solutions of HCl, HNO3, H2SO4, H3PO4, 20% (v/v) HF and 30% (v/v) NaOH. Up to 20% NaCl can be aspirated by the nebulizer for 1 hour without clogging.
PerkinElmer Spray Chambers for all of Your Superior quality Spray Chambers designed to provide maximum sensitivity and efficiency Save Time and Expense ■ Decreased sample introduction system installation and optimization time due to the preset nature of the spray chamber/nebulizer combination ■ More samples per hour due to minimal dead volume and efficient draining Unique Design Characteristics ■ The nebulizer port is oversized so that sample solution cannot build up around the nebulizer as it will in
Applications Baffled Cyclonic Spray Chamber Ryton® Scott Spray Chamber Ryton® Scott Spray Chambers The Ryton® Scott Spray Chamber is made from corrosion-resistant Ryton®, which is inert to most mineral acids including HF, aqua regia and all organic solvents normally used in ICP analyses. The Scott-type design minimizes pulsations from the peristaltic pump. The Type II, two-piece design ensures leak-free performance. The removable inner tube allows the chamber to be easily disassembled for cleaning.
torch modules and hardware Quick-change torch modules provide maximum efficiency in your lab Quick-Change Torch Module with Ryton ® Scott Spray Chamber and GemTip Cross-Flow Nebulizer Complete torch and sample introduction module including Demountable Single-Slot Torch, mounting block, 2 mm Alumina Injector, Ryton® Scott Spray Chamber and GemTip Cross-Flow II Nebulizer. Useful when a separate sample introduction is required for running different sample types.
torches and torch accessories Keep a replacement Torch on-hand to ensure maximum uptime and performance Demountable Quartz Torches Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0 – 3 slots, depending on your instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for aqueous solutions. 3-slot torches are typically used for organic analysis.
injectors and adapters Full selection of Alumina, Quartz and Sapphire Injectors and Support Adapters Quartz Injectors Alumina Injectors Alumina injectors are corrosion-resistant to all mineral acids including HF and aqua regia. They are also used with less volatile organic solvents, e.g., xylene. The 2.0 mm i.d. Alumina injector is shipped standard with all PerkinElmer ICP-OES instruments. A variety of sizes are available as an alternative to the standard injector.
Purge Windows and RF Load Coils Keep your instrument operating at peak efficiency with genuine sample introduction supplies Ceramic Interface Cone The Ceramic Interface Cone includes the Ceramic Cone, the Purge Window (09992731) and the Clamp. The Ceramic Cone is used between the plasma and the spectrometer. ICP Model Part No.
High-Performance Nebulizers with Excellent PerkinElmer nebulizers offer superb sample introduction for a wide variety of applications MicroMist Nebulizers The MicroMist micro-uptake glass concentric nebulizer offers high performance for limited sample volumes. MicroMists with sample uptakes 0.2 – 0.4 mL/min are fitted with a UniFit connector with 1.3 o.d. x 0.50 mm i.d. x 700 mm long sample tubing. MicroMists with sample uptakes 0.05 – 0.1 mL/min are fitted with a UniFit connector with 1.3 o.d. x 0.25 mm i.
Sensitivity and Precision PFA Teflon® Nebulizers The PFA-ST nebulizer features high purity, HF-resistance, and high performance, along with an exchangeable external sample uptake capillary. The sample uptake rate is controlled by the dimension of the external capillary or probe. For use with autosamplers. Requires a CTFE union (N8122355) to connect to the UltraClean autosampler probe. AllTeflon® construction, chemically inert. Chemically resistant–ideal for strong acids, alkalis, organics.
Superior Quality Spray Chambers for a PerkinElmer spray chambers provide maximum sensitivity and efficiency Baffled Quartz Cyclonic Spray Chamber 7 mm baffle, aux. gas port, drain line included and connects directly to ESI injectors. An adapter is needed to connect to other injectors. Description Part No.
Variety of Applications Cyclonic Spray Chambers PC 3 Spray Chamber The Cyclonic Spray Chamber relies on momentum to efficiently and quickly remove the larger droplets from the sample mist decreasing any opportunity for occlusion or agglomeration of the smaller droplets. The result is higher efficiency, better precision and faster washouts than other spray chamber designs.
injectors and adapters Full selection of Alumina, Quartz and Sapphire Injectors and Support Adapters Sapphire Injectors Alumina Injectors Sapphire Injector Tube, 2.0 mm i.d. Alumina injectors are compatible with twist type and cassette torch mounts. They are vacuum baked to reduce contamination. ■ 2.0 mm i.d. for use with HF-resistant (Ryton®) sample introduction system. Standard injector for aqueous solutions and less volatile organic solvents Description Part No.
torches, torch accessories and RF coils Ensure uptime — keep a replacement Torch on hand Demountable Quartz Torch The EasyGlide™ torch mount and alignment system used in the ELAN ICP-MS system is shown on the right. It is a demountable design that incorporates a quartz torch with a fully replaceable sample injector made of fused alumina, quartz or sapphire. ICP-MS Model Part No. ELANs all models N8122006 High Efficiency Demountable Quartz Torch Demountable Quartz Torch only.
mass spectrometer hardware and supplies Unique Detector and Ion Optic design Ion Optics PerkinElmer offers the industry’s only single-ion lens with the exclusive SwiftMount™ II cassette lens mount. The plug and play design makes changing the ion lens faster and simpler than ever before. No tools are required as the design incorporates a clean capture-and-release concept. Ion Lens Description ICP-MS Model Part No.
cones and accessories Tested and approved Sampler and Skimmer Cones Sampler and Skimmer Cones Precision-designed and manufactured, large-orifice sampler and skimmer cones provide superior long-term stability and resist clogging, allowing analysis under both high and low sample-uptake conditions. Nickel is a very rugged, long-lasting material for the majority of sample types, while platinum is the material of choice for more corrosive samples. The sampler cone, with a 1.
sample introduction kits Sample Introduction Kits provide a complete solution for your ICP-MS Applications Glass Cyclonic Sample Introduction System Part No. N8120518 System Includes: Twister Cyclonic Spray Chamber w/Helix Cyclonic Spray Chamber Mount MicroMist Micro-uptake Glass Concentric Nebulizer Offers high performance for limited sample volumes. Fitted with an EzyFit connector with 1.3 o.d. x 0.50 mm i.d. x 700 mm long sample tubing. Quartz Injector 2.0 mm i.d. Tygon Tubing (1 foot) Insert 1 ⁄4 in.
Find all of your Atomic Spectroscopy consumables quickly with our newly enhanced website With our extensive offering of consumables available you can now find what you need not only by Instrument model, but now by Product Category. Just filter your criteria online to find the product you’re looking for and add it to your shopping cart. It’s now easier than ever to place your order online. As always, you’ll see live product availability; pricing and delivery estimates.
service plans Dependable Service coverage to enhance your productivity and performance Maximize instrument performance and uptime From unplanned repair expenses to lost productivity, few events can be as disruptive as the failure of a key instrument. With a service and support plan from PerkinElmer, your lab will be protected from unplanned downtime and unexpected expense.
power conditioners NEW! PowerVar Power Conditioners Avoid all of the unnecessary costs - financial and otherwise - of equipment downtime Whatever your business, equipment that crashes can cause real problems for your entire operation. Damaged or compromised components, disrupted processes, lack of reliability . . . they all add up to frustration, broken schedules and costly downtime.
mercury analyzer PerkinElmer SMS 100 Mercury Analyzer Amalgamator Tube Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy The SMS 100 is a dedicated mercury analyzer for the determination of total mercury in solid and liquid samples using the principle of thermal decomposition, amalgamation and atomic absorption described in U.S. EPA Method 7473.
autosampler supplies Autosampler sampling probes and components AS-90/90A/90plus/91/93plus/S10 Sampling Probe Assemblies Stainless Steel Description Part No. Flame Sampling Probe Assembly, 0.6 mm i.d. Includes Stainless Steel Sampling Probe and Screw Fitting (B3000152) and Flame Capillary (B3000157– replaces B0196963) Tubing Assembly. FIAS™ Sampling Probe Assembly, 0.6 mm i.d.
Sample Vials, Racks and Supplies for a SPECIAL SAVINGS OFFERS from PerkinElmer! Save on Autosampler Vessels! Please contact your local sales office for more details. Delivering Enhanced Value and Outstanding Savings on the products you use most! Sample Vessels Translucent polypropylene vessels with excellent chemical resistance. Capacity Sample Trays AS-90/90A/90plus Sample Trays Description/Capacity Sample Vessel Size Part No. Tray A – 144 Tray B – 98** Tray C – 36 Blank Tray 4.
Variety of Autosamplers ESI Autosampler Supplies Racks and Rack Covers Standard Racks Description 10-Position 24-Position Adapter Plate* Size Diameter Part No. 4x6 28 mm 14 mm N0777228 N0777234 N0777235 *For Gemetec/Cetac ASX-100’s racks Micro Racks Description Size Diameter Part No. 21-Position 40-Position 60-Position 90-Position Cover for Micro Racks 3x7 4 x 10 5 x 12 5 x 12 14 mm 14 mm 8 mm N0777229 N0777230 N0777231 N0777232 N0777233 Description Size Diameter Part No.
Tubing, Connectors and Adapters for your PerkinElmer pioneered the use of flow injection techniques for atomic spectroscopy Adapter with Internal Thread ⁄4 in (6.4 mm) Internal Screw Thread 1 Type* A Description Part No. 1.8 mm o.d. nipple 3.3 mm o.d. nipple B0193342 B0506716 4 mm o.d. nipple B0196850 For the quartz cell B0196857 F 0.7 mm o.d. Pt/lr capillary nipple B0193873 G Two nipples to connect tubes to the pre-concentration accessory B0501580 Description Part No.
Flow Injection System Mixing/Separation Assembly Tubing Complete modular unit, consisting of two mixing manifolds with tubing adapters, a gas liquid separator with a PTFE membrane, five spare PTFE membranes, one PTFE tube (110 mm long) and one PTFE tube (300 mm long). Peristaltic pump tubing has a wall thickness of 0.84 mm. Part numbers are for a package of 12 pieces. Part No.
tubing and supplies Ensure reproducibility by replacing your SPECIAL SAVINGS OFFERS from PerkinElmer! tubing frequently Save when you purchase 2-packs of ICP PumpTubing Please contact your local sales office for more details. Delivering Enhanced Value and Outstanding Savings on the products you use most! Viton Tubing ■ Standard PVC Tubing ■ An economical high-performance material with great versatility for a wide range of uses Description Color 0.19 mm i.d. 0.25 mm i.d. 0.38 mm i.d. 0.76 mm i.d.
WhisperCool™ Chiller for ICP-OES and ICP-MS Water cooling systems (chillers) provide clean, reliable temperature controlled fluid for open tanks or closed loop cooling. The PolyScience WhisperCool Refrigerated Chiller is designed to deliver performance over a broad range of operating temperatures and conditions. For added operational safety, they also feature audible and visual alarms that alert you instantly when operating parameters exceed pre-set limits.
PerkinElmer Factory Tested and Approved PerkinElmer offers a full range of filters and regulators for your laboratory Acetylene Regulator Argon/Nitrogen Regulator For AA and ICP, this regulator can be used with argon or nitrogen and has a CGA 580 fitting. A color-coded hose with 1⁄4 inch SWAGELOK® fittings is also included. Description Part No.
Laboratory Products Parker Balston ® 73-099 AA Gas Purifier Air Dryer Filter Assembly with R250 Regulator For AA labs, this wall-mounted system designed to purify the compressed air and acetylene gases used in atomic absorption. It consists of two independent filtration systems, one for compressed air and one for acetylene. The unit also has a flashback arrestor on the acetylene line and a pressure regulator on the compressed air line. To filter compressed air for AA and ICP instrumentation.
PerkinElmer Pure Atomic Spectroscopy Whatever your application, you can depend on PerkinElmer Pure Standards to yield reliable, accurate results PerkinElmer offers a wide selection of atomic spectroscopy calibration standards. Each solution is supplied with a comprehensive Certificate of Analysis that documents the quality and reliability. Quality PerkinElmer Pure standards are prepared gravimetrically from high-purity metals and salts, using high-purity reagents.
Standards Single-Element Calibration Standards Element Symbol Matrix Starting Material 100 mL Part No. 500 mL Part No.
Atomic Spectroscopy Standards for your Instrument Calibration Standards Matrix Contents Vol. Part No. Instrument Calibration Standard 1 5% HNO3 5,000 μg/mL: Ca, K, Mg, Na 100 mL N9300218 100 mL N9300219 100 mL N9300220 100 mL N9300221 250 mL N0691580 100 mL N0691581 Instrument Calibration Standard 2 5% HNO3 Mixed Calibration Standards Matrix Contents Vol. Part No.
SPECIAL SAVINGS OFFERS ICP Applications from PerkinElmer! Save on Atomic Spectroscopy Standards when you purchase 2 or more! Please contact your local sales office for more details. Delivering Enhanced Value and Outstanding Savings on the products you use most! Interference Check Standards Matrix Contents Vol. Water Pollutant Standards Part No. Interference Check Standard 1 H2O/tr HNO3/0.
Atomic Spectroscopy Standards for your SPECIAL SAVINGS OFFERS from PerkinElmer! Save on Atomic Spectroscopy Standards when you purchase 2 or more! Please contact your local sales office for more details. Delivering Enhanced Value and Outstanding Savings on the products you use most! Instrument Calibration Standards Matrix Contents Vol. Part No.
ICP Applications Environmental Method Sets Environmental Standard Kit for non-DRC/Standard ICP-MS Instruments Description Environmental Standard Kit for non-DRC/Standard ICP-MS Instruments Part No.
Sample Digestion Block Systems PerkinElmer offers a variety of Sample Preparation Blocks (SPB) and accessories for your lab needs Features and Benefits ■ Ideal for any digestion / heating method which requires a temperature below 180 °C ■ Provides uniform temperature (+ / - 1.
DigiFILTER ™ The vacuum assisted Digi FILTER assembly provides a quick and easy way to filter samples prior to analysis. Increase lab productivity by filtering particulates from digested samples in a matter of seconds directly from the digestion tube. Available with a 0.45 or 1.0 micron hydrophilic Teflon® membrane.
PerkinElmer products — proven quality, reliability and results. THE WORLD LEADER IN ATOMIC SPECTROSCOPY PerkinElmer Sample Preparation Blocks! SAVE on packs of 1,000 Autosampler Cups or Vials! See pages 15 and 44 THGA Graphite Tubes only from PerkinElmer! See pages 20-21 SAVE on ICP Pump Tubing when you purchase 2 packs Ensure reproducibility by replacing your tubing frequently. See page 48 Available in 50 mL and 100 mL sizes. Teflon®-coated to resist aggressive, corrosive attack.