Operation Manual

2-14
2.2.2. RESOLUTION CHECK USING
THE TS-4348/UV TEST SET
NOTE
The TS-4348/UV Test Set can be used by the operator to check
the resolution of a monocular at any time.
NOTE
The TS-4348/UV Test Set can be used by Direct Support/Inter-
mediate Level to perform the resolution testing 180 Day Serv-
ice. If a system fails it must be tested on the TS-3895A/UV Test
Set.
NOTE
Verify the resolution of the monocular using the TS-4348/UV
Test Set at every opportunity. The resolution cannot be accu-
rately measured without the test set.
The following procedures are designed to check the performance
of the image intensifier.
a. Setup
Before using the TS-4348/UV Test Set to set up and familia-rize
yourself with its operation and the warnings and cautions associ-
ated with that test equipment.
NOTE
The resolution test must be performed in a darkened area.
Your eyes must be dark-adapted to perform this test. Review
the following test procedure before entering the dark area.
• Expect cosmetic blemishes, such as chicken wire, black
spots, and fixed-pattern noise, to stand out while viewing
through the TS-4348/UV Test Set when it is on the high light
level. This is acceptable.
The rejection of any MUNVM for cosmetic defects must be
based on an outdoor evaluation and not the TS-4348/UV Test
Set.
b. Low Light and High Light Resolution Test Procedure
Test the monocular for low light and high light resolution perfor-
mance according to the following steps.
(1)
Place the HIGH/LOW switch on the test set to the LOW position.