Installation manual

MonoSolar & Solar Panels Installation Manual Page 18 of 29
6.0 Taking the MonoSolar out of service
6.1 Switching off
The MonoSolar can be switched of by unplugging it, preferably in the morning or
evening, when the pump is not running.
6.2 Draining the system – Draining the tank
6.2.1 Let the tank cool down by running the domestic hot water until all lamps on
the display are off.
6.2.2 Immediately disconnect the electrical supply.
6.2.3 Drain with a hose connected to the drain cock at the base of the tank.
6.3 Draining the system – Draining the heat exchanger
6.3.1 Close the tap to the cold water inlet.
6.3.2 Disconnect the cold and hot water pipes from the MonoSolar.
6.3.3 Connect a hose into the cold-water inlet of the appliance and siphon the water
into a drain.
PLEASE NOTE!
After you have drained the appliance, there will be some water left in the heat
exchanger. In case of removal for transport, open ends need to be sealed.
7.0 Warranty
Warranty information is provided with the MonoSolar and solar panels.
Warranty does not cover the following:-
Costs of collection.
Transport costs.
Admin costs.
Transport damage.
Consequential damage (e.g. Company damage, water damage, fire damage).
PLEASE NOTE
The responsibility for giving compensation lies firstly with the installer /
supplier where the appliance is acquired.