Installation manual

5.5 Installing the Solar Panel Sensor
5.5.1 The panel sensor must be fixed in place into the left or right opening on the
side of the panel by means of a clamping arrangement. Note that the sensor
may be supplied with the panel and clamped in position. Check the screws for
tightness.
5.5.2 Seal the sensor opening with insulating material.
5.6 Electrical Wiring/connections
5.6.1 The electrical wiring of the MonoSolar is complete and should not be altered
or adjusted in any way. The circuit diagram is given in the Appendix.
5.6.2
Connecting the panel-pump
Make the electrical connections to the pump according to the circuit diagram.
5.6.3
Connecting the panel sensor
Connect the plug of the panel sensor to the connector block of the MonoSolar
with a two-core cable.
PLEASE NOTE:
Make sure that the sensor wire doesn’t come in contact with the panel
pipes. The high temperatures of the pipes can damage the insulation of
the electrical wires!
5.7 Connecting the display to the wall
5.7.1 If preferred the display can be disconnected and fitted remotely on a wall. For
this you need a four-core cable and a four-way connector block (available
from Atmos).
5.7.2 Disconnect the display electrical connections from the control box.
5.7.3 Unscrew the display and replace it with the cover. Screw the spare cover unto
the casing.
5.7.4 Remove the front of the display by lifting the sides with a screwdriver.
5.7.5 Fit display on the wall and connect the four-core cable between the display
and the control panel, observing current electrical regulations. Refit the lid.
Figure 5.6
MonoSolar & Solar Panels Installation Manual Page 16 of 29