Operating instructions
Atmos InterCombi
1/2
ATMO
S
User Operating Instructions for Atmos InterCombi HE32 Condensing Boiler
First ask your installer to instruct you thoroughly about filling, de-
aerating and general use of the appliance and the total installation.
General operation
The Atmos InterCombi wall-mounted gas boiler is a balanced flue
appliance, designed for delivering heat to the water of a central heating
system and domestic hot water. The Atmos InterCombi wall-mounted
gas appliance is a modulating high efficiency (Sedbuk A) boiler. This
means that the power is adjusted to the heat demand.
In the aluminium heat exchanger, two separate copper circuits have
been integrated. Because of the separated circuits for central heating
and hot water, the heating and the hot water supply can operate
independently of each other. However, they cannot work simultaneously.
The hot water supply has priority over the central heating.
The appliance has been provided with an electronic burner controller that
controls the fan with the heat demand from the heating system or the hot
water supply, opens the gas valve and ignites the burner, continuously
monitors the flame and controls it dependent on the power required.
Central Heating (CH) operation
If the room temperature is below the room on/off thermostat temperature
and there is no hot water demand, the boiler will switch to CH operation.
The controller adjusts the fan speed, and hence the heating power,
according to the set CH supply water temperature, the latter being
displayed on the temperature display (during CH operation and
adjustable between 30 and 90 °C, using + / - buttons). The appliance
circulation pump has an overrun time of 1 minute (factory setting, but can
be adjusted) to dissipate the heat. Also, the pump will automatically run
once every 24 hours to prevent it from getting stuck (if there is no CH
operation).
Domestic hot water (HW) operation
Domestic hot water operation will automatically start as soon as more
than 2 l/min hot water is demanded. During hot water operation, CH
operation is interrupted. The appliance pump does not run for HW
operation.
During hot water operation, the hot water set temperature is displayed on
the temperature display (adjustable between 40°C and 65°C, using + / -
buttons ). For a quick supply of domestic hot water, a comfort function has
been provided in the controller. This function keeps the heat exchanger at
the correct temperature. This comfort function can be set using the hw
store button (E) and has the following settings:-
• Off: (Both LED’s 5 & 6 off.) The heat exchanger is not kept warm,
delaying the supply of domestic hot water. When there is no
requirement for domestic hot water, the comfort function can be
switched off.
• On: (LED 6 on) The comfort function of the appliance is
continuously activated. The appliance always supplies domestic
hot water immediately.
• Eco: (LED 5 on) The comfort function is self-learning. The appliance
is inactivated during the night or after a long absence. The appliance
adjusts to the user pattern of the domestic hot water requirements.
The Eco mode is the most efficient hot water method and should
normally be used.
The Atmos InterCombi boiler has the CE quality mark and an IP44
enclosure. The boiler delivers 9 litre per minute at 60°C (this
corresponds to 15 litre per minute at 40°C). This means that a 120 litre
bath can be filled with hot water at 40°C within 8 minutes.
Displays
Controls
1. On/Off LED 6. Comfort function On LED A. On/Off button E. Comfort button
2. CH LED 7. Service display B. CH/Hot water switch button F. Service button
3. Hot water LED 8. Fault LED C. – button G. Reset button
4. Temperature display 9. CH pressure gauge D. + button
5. Eco mode LED
Operating conditions on the service display (7):
—
Off (frost protection active)
2
Self-test
5
CH operation
Stand-by
3
Fan
6
Domestic hot water operation
0
Pump overrun CH
4
Ignite burner
7
Heating the appliance (heat exchanger)
1
Required temperature reached
When the red fault LED (above the Reset button) is on, the burner controller has detected a fault. In the service display, a flashing fault code appears.