Technical data
52
10. TECHNICAL SPECIFICATIONS
Appliance category
B13; B33; C13; C 33; C 43; C53; C63; C83
Gas inlet pressure
20 mbar
Suitable for gas
II
2
H
3
P
Technical dat
a
InterSystem HE 26
InterSystem HE 40C
CH
Heat power input (gross)*
kW
8.0
–
30.3
8.7
–
47.1
Heat power input (net)*
kW
7.2
–
27.3
7.8
–
42.5
Heat output at 80/60°C*
kW
7.0
–
26.2
7.0
–
40.9
Heat output at 50/30°C*
kW
7.7
–
26.8
Max. CH w
ater pressure
bar
3 (see note 1)
3 (see note 1)
CH operating pressure
bar
1
–
2 (see note 2)
1
–
2 (see note 2)
Max. CH water temperature
°C
90
90
Other data
Gas consumption
m
3
/h
0.85
-
3.25
0.81
–
4.00
Electrical data
Mains voltage
V
230
230
Protection class
IP44 (B(.)=IP20)
IP44 (B(.)=IP20)
Consumed power: full load
W
105
105
Consumed power: partial load
W
40
40
Consumed power: standby
W
2.4
2.4
Overall dimensions and weight
Height
mm
810
810
Width
mm
450
450
Depth
m
m
270
270
Weight
kg
39
37
Registratrion
GC registration number
41
-
249
-
05
41
-
249
-
07
*The maximum CH power is set to 50% of the highest value at the factory (see Setting CH power).
Notes 1 - Safety discharge valve is 3 bar.
2 – Min pressure 1 bar (expansion vessel pre-charge is 1 bar).