Installation Guide
Assembly Instructions
Run water through the
unit for one minute, and
make sure there are no
leaks
01
06
05
02
04
03
Disconnect the cable
from the PCB within the
unit. (Figure 3)
Remove the appliance covers
(Figure 2).
Connect the incoming water line
to the heater inlet (on right side),
and connect the outgoing water
line to the heater outlet.
Use a hose that can withstand
pressure up to 8 bar (Figure 5).
Mount the unit on the wall with 4 screws at the marked points.
(Figure 4)
Make sure the unit is horizontally level, with water inlets and
outlets at the bottom. (Figure 5)
Make sure power to the unit is shut off by means of the dedicated
circuit breakers on the main electrical panel.
Run the power cable wires from the circuit breakers on the main
electrical panel to the water heater.
Connect the power cable to the terminal block within the unit.
Make sure the correct breaker size and wire gauge have been used.
Make sure all wire connections are tight and secure.
Make sure the unit is connected to a ground in accordance with
applicable codes. (Figure 6)
6