Full Product Manual

Technical Information
Electrical Specications
Thermo Boost
10.5 kW
Thermo Boost
14 kW
Heating elements 2 2
Watts 10,500 W 14,000 W
Kilowatts 10.5 kW 14 kW
Voltage 240 V 240 V
Circuit breaker amperage 50 A 70 A
Breaker/relay double-pole double-pole
Total connection load 43.7 A 58 A
Cable size (minimum) 6 AWG 4 AWG
Plumbing Specications
Minimum water ow to activate unit 0.5 gpm
Working pressure 7–115 psi (0.5–8 bar)
Tested pressure 230 psi (16 bar)
Water connections 1/2" NPT
Flow Rate
Temperature Rise
Δt (°F)
Flow Rate (gpm)
Thermo Boost
10.5 kW
Thermo Boost
14 kW
77 0.87 0.95
45 1.7 2.3
35 2.2 2.9
Physical Dimensions
Height Width Depth Weight
9
1
/
2
in.
(235 mm)
11
3
/
8
in.
(289 mm)
4
1
/
8
in.
(104 mm)
5 lb 11oz
(2.58 kg)
3