Warranty

Electrical Diagram
1 2
45 3
L1
N
P
5
Technical Information
1. Switch (Option A): Off/On
Switch (Option- B): Off/1/2/3
(1-Medium, 2- High, 3- Very high)
2. Heating element (Option A):
1 Heating element
3. Thermostat set to cut off at 135°F
4. Heating elements (Option- B):
2 Heating elements:
Heating Position 1 – Medium
Heating Position 2 – High
Heating Position 3 – Very High
5. Pressure Switch (Option A):
1 Microswitch
Pressure Switch (Option B):
2 Microswitch
Physical Dimensions
Height Width Depth
2
1
/
4
inch (58.9 mm) 2
1
/
2
inch (62.8 mm) 2
1
/
2
inch (62.8 mm)
Electrical Specications
Heating elements 2
Watts 3,000 W
Voltage 110 V
Circuit Breaker Amperage 30 A
Plumbing Specications
Minimum water ow to activate unit 0.3 gpm
Working pressure 3.67-58 psi
Water connections 1/2" NPT