Table 7-8 Read Incrementing Address Characteristics
Action Supported/
Not Supported
Maximum number
of bytes
Non-aligned access
accepted
8-bit read NS - -
16-bit read NS - -
32-bit read S 1064 No
64-bit read NS - -
Word or byte address 32-bit aligned
Accepted Logical Addresses 0xFE
Accepted destination keys 0x20 at power on
Accepted address ranges 0x00 0000 0000 – 0x00 0000 0109
Incrementing address Incrementing address only
The RMAP read incrementing address command is supported in the SpaceWire router. The read
incrementing address is used to read a continuous block of registers from the SpaceWire router, e.g.
the complete group adaptive routing table can be read in one command or all the status registers for
the SpaceWire links can be read in one command.