Automatic Gain Control For a correct demodulation the signal conditioner needs appropriate internal signal
amplitude. To control the input signal the ATA5283 has a build in digital AGC. The gain
control circuit regulates the internal signal amplitude to the reference value (Ref2, Fig-
ure 4). It decreases the gain by one step if the internal signal exceeds the reference
level for two periods and it increases the gain by one step if eight periods do not achieve
the reference level. In the standby listen mode the gain is reset to the maximum value. If
a valid preamble signal (192 valid carrier clocks) is detected the automatic gain control
is activated.
Note: With the variation of the gain the coil input impedance changes from high impedance to
minimal 143 kΩ because of the internal regulator circuit (see Figure 10).