Datasheet

12
4266C–CAN–03/08
AT89C51CC03 UART Bootloader
Example
Flow Description: Read
Command
HOST : 05 0000 04 0000 7FFF 01 78
BOOTLOADER : 05 0000 04 0000 7FFF 01 78 . CR LF
Blank Check ok
BOOTLOADER : 05 0000 04 0000 7FFF 01 70 X CR LF CR LF
Blank Check with checksum error
HOST : 05 0000 04 0000 7FFF 01 70
BOOTLOADER : 05 0000 04 0000 7FFF 01 78 xxxx CR LF
Blank Check ko at address xxxx
HOST : 05 0000 04 0000 7FFF 01 78
Host
Bootloader
Display Command
’X’ & CR & LF
RD_WR_SECURITY
Wait Display Command
Read Data
Send Security Error
Send Display Data
Send Display Command
Wait Checksum Error
Wait Display Data
Wait Security Error
OR
COMMAND ABORTED
COMMAND FINISHED
Send Checksum Error
COMMAND ABORTED
’L’ & CR & LF
OR
"Address = "
All data read
Complete Frame
"Reading value"
CR & LF
All data readAll data read
COMMAND FINISHED
Checksum error