Datasheet

108
AT89C5132
4173C–USB–07/04
Asynchronous Modes
(Modes 1, 2 and 3)
The Serial Port has one 8-bit and two 9-bit asynchronous modes of operation. Figure 82
shows the Serial Port block diagram in asynchronous modes.
Figure 82. Serial I/O Port Block Diagram (Modes 1, 2 and 3)
Mode 1 Mode 1 is a full-duplex, asynchronous mode. The data frame (see Figure 83) consists of
10 Bits: one start, eight data Bits and one stop bit. Serial data is transmitted on the TXD
pin and received on the RXD pin. When data is received, the stop bit is read in the RB8
bit in SCON register.
Figure 83. Data Frame Format (Mode 1)
Modes 2 and 3 Modes 2 and 3 are full-duplex, asynchronous modes. The data frame (see Figure 84)
consists of 11 Bits: one start bit, eight data Bits (transmitted and received LSB first), one
programmable ninth data bit and one stop bit. Serial data is transmitted on the TXD pin
and received on the RXD pin. On receive, the ninth bit is read from RB8 bit in SCON
register. On transmit, the ninth data bit is written to TB8 bit in SCON register. Alterna-
tively, the ninth bit can be used as a command/data flag.
Figure 84. Data Frame Format (Modes 2 and 3)
Transmission (Modes 1, 2
and 3)
To initiate a transmission, write to SCON register, setting SM0 and SM1 Bits according
to Table 89, and setting the ninth bit by writing to TB8 bit. Then, writing the byte to be
transmitted to SBUF register starts the transmission.
Reception (Modes 1, 2 and 3) To prepare for reception, write to SCON register, setting SM0 and SM1 Bits according to
Table 89, and set the REN bit. The actual reception is then initiated by a detected high-
to-low transition on the RXD pin.
TB8
SCON.3
IBRG
CLOCK
RXD
TXDSBUF Tx SR
Rx SR
SM1
SCON.6
SM0
SCON.7
Mode Decoder
M3 M2 M1 M0
RI
SCON.0
TI
SCON.1
Mode & Clock
Controller
SBUF Rx RB8
SCON.2
SM2
SCON.4
T1
CLOCK
PER
CLOCK
Mode 1 D0 D1 D2 D3 D4 D5 D6 D7
Start bit 8-bit data Stop bit
Modes 2 and 3 D0 D1 D2 D3 D4 D5 D6 D8
Start bit 9-bit data Stop bit
D7