Owner's Manual
25570 Rye Canyon Rd. Valencia, California 91355
(661) 294-7999 voice (661) 294-1115 fax
techinfo@activethermal.com www.activethermal.com
Active Thermal Management
The trusted name in thermal protection…
Parts list – before proceeding, check that you have received all of the following:
(1) control unit
(2) or (4) (depending on model) 120mm fans
(2) or (4) finger guards
(1) power supply
(1) thermal sensor/probe
System 2 Kit and 2 + 2 Kit Instructions
NOTE: Read these instructions as the System 2 Kit and 2+2
Kit were recently updated.
The Active Thermal Management System 2 and 2 + 2 kits are self-contained ventilating systems
for small-to-midsize enclosures with moderate heat loads. The major individual components are
the 2-speed control unit, power supply, temperature sensor/probe, and two (2) or four (2+2)
4.7"/120mm fans.
A quick overview of the installation process:
1. The fans are located at the point(s) where heated air is to be exhausted from the enclosure. If
desired, 1 or 2 fans can be used to bring room air into the enclosure, while the other 1 or 2
exhaust the heated air. See “ Cooling the Mid-size Enclosure” on the Downloads page at
activethermal.com for typical fan locations.
2. The control unit is mounted in a convenient location.
3. The thermal sensor is positioned where it will sense air and/or equipment temperatures.
4. The fan, power supply, and thermistor wires are connected to the control unit.
5. The power supply is plugged into a convenient source of 120 volt 60Hz power.
6. The completed installation is tested.
Detailed instructions:
Note: Do not plug the power supply into an outlet until directed to do so.