Manual
AT-HDVS-200-TX-WP / AT-HDVS-200-TX-WP-BLK
58
Commands
RS232zone
Sends commands to the connected display. Refer to the User Manual of the display device for a list of available 
commands. Brackets must be used when specing the command argument. The command line must not contain 
any spaces.
Syntax
RS232zone[X]
Parameter Description Range
X Command String
Example
RS232zone[command]
Feedback
RS232zone[command]
RxRSparaZ
Sets the baud rate, data bits, parity bit, and stop bits for the RS-232 1 port on the AT-HDVS-200-RX. Parameter V 
must be set to 1. Each argument must be separated by a comma; no spaces are permitted. Brackets must be used 
when specing the arguments. Use the sta argument, without brackets and including a space, to display the current 
settings.
Syntax
RxRSparaZV[W,X,Y,Z]
Example
RxRSparaZ1[115200,8,0,1]
RxRSparaZ1 sta
Feedback
RxRSparaZ1[115200,8,0,1]
RxRSparaZ1[115200,8,0,1]
Parameter Description Range
V Port 1
W Baud rate 2400, 9600, 19200, 38400, 56000, 57600, 115200
X Data bits 7, 8
Y Parity bit None, Odd, Even
Z Stop bits 1, 2