Manual

AT-HDVS-200-TX-WP / AT-HDVS-200-TX-WP-BLK
47
CSpara
Sets the baud rate, data bits, parity bit, and stop bits for the serial device. Use the sta argument to display the
current serial port settings. Each argument must be separated by a comma; no spaces are permitted. Brackets
must be used when executing this command.
Syntax
CSpara[W,X,Y,Z]
Example
CSpara[115200,8,0,1]
CSpara[sta]
Feedback
CSpara[115200,8,0,1]
CSpara [115200,8,0,1]
Parameter Description Range
W Baud rate 2400, 4800, 9600, 19200, 38400, 57600, 115200
X Data bits 7, 8
Y Parity bit None, Odd, Even
Z Stop bits 1, 2
Commands
CTRST
Sets the picture contrast. Use the sta argument to display the current setting.
CtlType
Sets the control type for communication with the display device.
Syntax
CTRST X
Syntax
CtlType X
Parameter Description Range
X Contrast 0 ... 100, sta
Parameter Description Range
X Value rs-232, ip, cec, sta
Example
CTRST 65
Example
CtlType cec
Feedback
CTRST 65
Feedback
CtlType cec