Manual

AT-HDVS-200-TX-WP / AT-HDVS-200-TX-WP-BLK
44
Blink
Enables or disables blinking of the DN button on the front panel. When set to on, the DN button will ash red and
can be used to physically identify the unit on a network. The DN button will ash until the Blink o command is
executed. on = enables DN button blinking; o = disables DN button blinking; sta = displays the current setting. The
default setting is o.
Syntax
Blink X
Parameter Description Range
X Value on, off, sta
Example
Blink on
Feedback
Blink on
Commands
Broadcast
Enables or disables broadcast mode. By default, broadcast mode is set to o. When set to on, changes in the web
GUI will also be aected on the control system (if connected), via TCP/IP. To separate control between web GUI and
Telnet, set this feature o. on = enables broadcast mode; o = disables broadcast mode; sta = displays the current
setting.
Syntax
Broadcast X
Parameter Description Range
X Value on, off, sta
Example
Broadcast on
Feedback
Broadcast on
BRT
Sets the picture brightness. Use the sta argument to display the current brightness setting.
Example
BRT 60
Syntax
BRT X
Parameter Description Range
X Value 0 ... 100, sta
Feedback
BRT 60