Manual
AT-HDVS-200-TX-WP / AT-HDVS-200-TX-WP-BLK
41
Commands
ASwFstTime
Sets the time interval, in seconds, before the unit switches to the input used by a newly-powered or connected
device. Use the sta argument to display the current setting.
ASwOutTime
Sets the time interval, in seconds, before the unit automatically switches to another active input if no signal is
received from the current input. Use the sta argument to display the current setting.
ASwPrePort
Sets the default input to be used for auto-switching, once no A/V signal is detected from the currently active port.
Use the sta argument to display the current setting.
Syntax
ASwFstTime X
Syntax
ASwOutTime X
Syntax
ASwPrePort X
Parameter Description Range
X Time interval 10 ... 600, sta
Parameter Description Range
X Time interval 3 ... 600, sta
Parameter Description Range
X Port 1 = HDMI IN 1
2 = HDMI IN 2
3 = VGA IN
Prev = Previous
Example
ASwFstTime 10
Example
ASwOutTime 10
Example
ASwPrePort 1
Feedback
ASwFstTime 10
Feedback
ASwOutTime 10
Feedback
ASwPrePort 1










