Manual
AT-HDVS-200-TX-WP / AT-HDVS-200-TX-WP-BLK
25
Display Auto Power On
Sends the command to power-on the display when an A/V signal is detected. Click the toggle to enable or disable
this feature. Otherwise, set to DISABLED.
Display Auto Power O
Sends the command to power-o the display when an A/V signal is no longer present. Click the toggle to enable or
disable this feature. Otherwise, set to DISABLED.
Power Button Lock
Allows the DISPLAY button, on the front panel, to be locked, preventing accidental operation when the product is in
use. Click the toggle to enable or disable this feature.
Lamp Cool Down Timer
Sets the cool-down interval, in seconds, before the projector can be powered-o. During this time interval, the
projector will not accept any commands until the “power o” command has been processed and the projector lamp
has completed the cool-down cycle. Range: 0 to 300.
Display Warm Up Timer
Sets the time interval, in seconds, between when the display is powered on and when the DISPLAY button, on the
front panel, will be locked. Range: 0 to 300.
Auto Power O Timer
Sets the time interval, in seconds, between when the loss of A/V signal is detected and when the “Display O”
command is sent. Range: 5 seconds to 1 hour.
Control Type
Sets the control method for sending commands. The following options are available: RS-232, IP, CEC.
Feedback Verify
Sets the feedback verication state. Click the toggle to enable or disable this feature. The following options are
available.
System Settings
Setting Description
RS-232 RS-232 is used to send commands.
IP Commands are sent over IP.
CEC Uses CEC to send commands.
The Web GUI
Setting Description
On This is the default setting. The AT-HDVS-200-TX-WP will make four attempts to
send the command, if the feedback string is not acknowledged. After the fourth
attempt, the process will fail.
O Sends the command and ignores the feedback string.