Owner`s manual

OWNER’S MANUAL
AtlasSound.com
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333 FAX (800) 765-3435
©2008 Atlas Sound LP. All rights reserved.
Atlas Sound is a trademark of Atlas Sound LP. Printed in China.
ATS003211 RevA 8/08 7
Specifications are subject to change without notice
ECS-3
utility consumption time periods, such as heat waves. Another factor would be from voltage drops in
AC lines due to long transmissions. The ECS-3 will not only inform you if one of these conditions
occurs, but under extreme variances in the AC Mains, it will shut the power to the equipment off.
The Abnormal Voltage indicator on the front panel will flash if the AC Mains is between 128VAC and
132VCA or 107VAC and 101VAC. This is to inform you that a surge occurred and may have damaged
voltage sensitive equipment. If an extreme voltage swing occurs above 132VAC or below 101VAC,
the ECS-3 Extreme Voltage Shutdown (EVS) protection circuit will automatically activate and turn all
outlets off until it is manually reset.
The ECS-3 offers sequenced power management control, along with noise filtering and spike/surge
protection making it the most compact, effective power management protection system on the market
today.
Key Features
3 Sequencer Timing Sections Fixed 3-Second Intervals, 6 Seconds Total
9 Total Outlets Are Provided
6 Rear Panel Outlets Are Sequenced In Three Steps
2 Front Panel and 1 Rear Panel Unswitched Convenience Outlets
RFI Noise Filtering to Reduce Radio Frequency Interference
EMI To Reduce Electromagnetic Interference
Dual Clamping Spike & Surge Suppression, DCS Circuitry
Front Panel Digital AC Mains Voltmeter
LED Indication of Reversed “Live” and “Neutral” Wiring
Abnormal AC Line Voltage Indicator for Voltages Between 102V–107V
or 128V–132V
Extreme Voltage Shutdown (EVS) Below 102V or Above 132V AC Line
Circuit Breaker Protection @ 15A Indicated by “Breaker Open” Indicator
Front Mounted Pull-out LED Light With 2-Position Dimmer
Rear Mounted XLR Connector for 12VDC LED Lamp
External Switch Sequence Trigger Activation
External DCV Sequence Trigger Activation 5-24VDC
24VDC Sequence Trigger Output for Optional External AC Outlet