ECS-3
ECS-3 SPECIFICATIONS
General
Type Power Sequencer, Power Conditioner & Suppressor
Sequencer Sections 3, Fixed Time of 3 Seconds Between “On” Seq. 2 & 3, “Off” 2 & 1
Load Rating 15A
Front Panel
Outlets 2 Unswitched
Lights 1 Pull out LED with dimmer switch
Activation Switch Momentary
Circuit Breaker 15A resettable
AC Mains Voltmeter Three digits digital
Indicators Sequencer Sections 1, 2 & 3, Abnormal Voltage, AC Fault,
Breaker Open, Wiring Fault
Rear Panel
AC Outlets 7 Outlets total, Sequence Section 1 (3 outlets), Sequence
Section 2 (2 Outlets), Sequence Section 3 (1 outlet),
Unswitched (1 Outlet).
External Switch Activation Trigger
Momentary contacts, 2 position Euro/Phoenix type connector
External Voltage Activation Trigger
5-24VDC continuous, 10 mA, 2 position Euro/Phoenix type
connector
DC Output 24VDC 100mA output paralleled to Sequencer Section 3 timing.
LED Light Socket XLR Socket to provide 12VDC for optional 18” Gooseneck
Lamp.
LED Light Switch Two position On/Off
Grounding Terminal Hand Screw Type terminal to chassis ground.
AC Mains Power Cord 9' (3 Meters) 14-gauge
Technical Data
Current Rating 15 amps
Operating Voltage 102 - 132VAC
High Voltage Surge Protection Trigger at 133VAC, 1 ms typically
Low Voltage Protection Trigger 101VAC, 1 ms typically
Voltmeter Accuracy ±1.5VAC
Spike Protection Modes DCS (Dual Clamping Suppression) Circuitry on incoming AC
Mains and each Sequential Section output.
Min. Spike Clamping Voltage 460 VRMS @ 3,000A
Max. Spike Clamping Voltage 6000V