Owner`s manual
– 9 – AtlasSound.com
Specifications are subject to change without notice.
Owner’s Manual
ECM-15SH
AC
Power Conditioner & Suppression Module
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
ECS-6RM Sequencer Controller Interface with ECM-15SH
To get maximum use of the ECM-15SH we suggest using the ECS-6RM controller. When the two are interfaced the ECS-6RM
controller not only can remotely turn on the ECM-15SH but it can monitor the AC Mains Voltage and Current of the ECM-15SH. When
mated, the microprocessor in the ECS-6RM can determine if there are any potentially damaging AC Voltages present at the ECM-15SH
and shut it Off before damage can occur to sensitive equipment connected.
1. ECMcontrolports–Upto6ACMaincircuitscanbeactivatedormonitoredbytheECS-6RM.EachECMcontrolportconnects
to one of the following ECM module, ECM-20M, ECM-15SH, ECM-20SH and the ECM-20. For connection between the ECS-
6RM and an ECM modules use a 5 conductor cable that is a minimum of 22-gauge wire. We suggest using CAT5 cable due
tothecommonavailability.PayspecialattentiontotheportconnectionsandDONOTMISSWIREordamagemayoccur.The
distance between the ECS-6RM and an ECM module can be up to 1000'.
(+) = 5VDC, G = Circuit Ground, V = AC Voltage Status Signal, A = AC Current Status Signal, D = Fault Status Signal, all signals
are of low voltage and current.
Single ECM-15SH Control Port
2. RelayContacts–EachChanneloftheECS-6RMalsohasaRelaycontactthatworksinconjunctionwiththeECMcontrolport.
Sequencing and timing of these connections are the same as the corresponding ECM channels. Example: Sequence 1 ECM
PortoutputworksatthesametimesCH1Relaycontact.Note:AllECMmodulescanbetriggerusingtheRelaycontactsto
activate the ECM module.
Relay Contacts