Using the ECM-15SH as a standalone unit
The ECM-15SH can be used as standalone unit for local equipment protection. It does not need to be connected to an ECS-
6RMtooperate.YoustillgetprotectionagainstACspikefromlightningorshortpowersurgesandyougetalltheEMI/RFIpower
conditioning and filtering. What you do not utilize is the extreme Voltage Shutdown (EVS) protection and Voltage and Current status
readings. The ECM-15SH must be connected to the ECS-6RM to get the entire benefits of the ECM-15SH. To active the ECM-15SH via
an external contact closure or switch, place the slide switch to “External Trigger” and apply the contacts across terminals “+” and “D”
shorting them together.
Remote Activation via Switch or DCV Trigger
The ECM-15SH can be used as standalone unit for local equipment protection. It does not need to be connected to a ECS-6RM to
operate.YoustillgetprotectionagainstACspikefromlightningorshortpowersurgesandyougetalltheEMI/RFpowerconditioning
filtering. What you do not utilize is the extreme Voltage Shutdown (EVS) protection and Voltage and Current status readings. The ECM-
15SH must be connected to the ECS-6RM to get the entire benefits of the ECM-15SH. To active the ECM-15SH apply DCV 5 -24VDC
to the “+” and “G” terminals.
Wiring With an ECS-6RM Sequencer Controller
Example–ECS-6RMwiredto4ECM-20orECM-20MModulesintheECM-RACEWY6andtwoseparateECM-15SHandECM-20SH
modules.