Owner`s manual
– 7 – AtlasSound.com
Specifications are subject to change without notice.
Owner’s Manual
ECM-15SH
AC
Power Conditioner & Suppression Module
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
Panel Features
1. Trigger / Status Port Pin Identification -Allsignalsareoflowvoltageandcurrent.Note:Alldatasignalsarelowvoltageunder5V.
DO NOT MISS WIRE or damage may occur.
A. (+)requiresaminimumof5-24VDCtoactivatethemodulewith5mAofcurrent.Note:TheDCVcanbesuppliedfromany
source. The EVS protection requires the ECS-6RM for operation.
B. G = Circuit Ground, Must be of the same circuit as the DCV source.
C. V = AC Voltage Status Signal, this signal reports back to the ECS-6RM the Incoming AC Mains Voltage to the ECM module.
D. A = AC Current Status Signal, this signal reports back to the ECS-6RM the AC Mains Current draw at the ECM module.
E. D = Fault Status Signal, reports to the ECS-6RM fault conditions of an ECM module.
2. External Trigger / Manual On Switch–TheECS-15SHhasamanualoverrideswitchallowingittobeusedasalocalPower
Conditioner and Surge Suppressor. For it to be remotely monitored and activated the switch must be in the “External Trigger”
position.
3. Incoming AC LED–ThisLEDwillilluminateRedwhentheECMhasincomingACpowerpresentatthemodule.ThisLEDmustbe
ontooperate.Note:IfthisLEDisnotilluminatingcheckthefollowing:1)Theunitispluggedin,2)TheACMainsBreakerfeeding
the AC leg to the ECM module is On, 3) The internal fuse has been damaged. This should only be inspected by an authorized
technician.
4. Active LED–ThisLEDwillilluminateGreenwhentheECMmoduleManualSwitchisintheONpositionorthetriggercircuithas
sensedtheproperDCVtoactivatethepoweroncircuit.Note:IfconnectedtotheECS-6RMandtheEVScircuitisactivatedthis
LED will not be on. The Channel Status LED on the ECS-6RM will flash indicating a problem and will not turn the ECM module on
until the AC Mains voltage is stable.
5. AC Fault LED–IfdamagetotheSpikeSuppressioncircuitoccurredthisLEDwillilluminateRED.ThisLEDwillnotturnoffuntil
repaired. Have the ECM module inspected by a qualified technician.
6. AC Mains Outlet–Two120VAC15Aoutlets.
7. AC Mains Power Cord–9'(3m)14-gauge
ECM Data Wire and Distance
The ECM-15SH is one of four different types of ECM Modules requiring the same interface connectivity to the ECS-6RM. All ECM
Modules can be interfaced with the ECS-6RM. For connection between the ECS-6RM and an ECM module, use a 5 conductor cable
that is a minimum of 22-gauge wire. We suggest using CAT5 cable due to the common availability and low cost. Heavy gauge wire or
cable with a high voltage rating are not needed because the data signal and supply voltage are low current. Pay special attention to the
portconnectionsandDONOTMISSWIREordamagemayoccur.ThedistancebetweentheECS-6RMandtheECMModulecanbeup
to 1000'.