Owner’s Manual ECM-15SH AC Power Conditioner & Suppression Module ECM-15SH AC Power Conditioning & Suppression Module 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 –1– Specifications are subject to change without notice. AtlasSound.
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual Table Of Contents Introduction...............................................................................................................................................................3 Key Features.............................................................................................................................................................3 Applications......................................................................
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual Introduction The Atlas Power ECM-15SH is a 120V 60Hz Electrical Control Module (ECM), 15A Single Housing (SH) Power Conditioner and AC Spike Suppressor that is designed to be used as a standalone unit or in conjunction with an Atlas Power Sequence controller ECS-6RM or the ECS-3 up to a 1000' away. The slim compact unit is designed to fit almost anywhere, even behind a Flat Screen Panel.
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual CAUTION – When Installing the Product • Plugging in or unplugging the power cord with wet hands may result in electric shock. • Never move the unit with the power cord plugged into the wall, as damage to the power cord may result. • When unplugging the cord from the wall, grasp the plug, NOT the cord.
fier A35 d 35W Engineered ound HINA Owner’s Manual ECM-15SH AC Power Conditioner & Suppression Module Safety Instructions The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN ATTENTION ´ RISQUE DE DECHARGE ELECTRIQUE -NE PAS OUVRIR.
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual Internal Features of the ECM-15SH – Protection behind the panel • EMI/RFI Filters – ECM filters for unwanted Radio Frequency Interference (RFI) that is commonly introduced into the AC lines by nearby radio transmitters or wireless products. EMI filters are incorporated to reduce noise from Electromagnetic Interference (EMI) produced by such items as electric motors, switching power supplies and lightning.
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual Panel Features 1. Trigger / Status Port Pin Identification - All signals are of low voltage and current. Note: All data signals are low voltage under 5V. DO NOT MISS WIRE or damage may occur. A. (+) requires a minimum of 5-24VDC to activate the module with 5mA of current. Note: The DCV can be supplied from any source. The EVS protection requires the ECS-6RM for operation. B.
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual Using the ECM-15SH as a standalone unit The ECM-15SH can be used as standalone unit for local equipment protection. It does not need to be connected to an ECS6RM to operate. You still get protection against AC spike from lightning or short power surges and you get all the EMI/RFI power conditioning and filtering. What you do not utilize is the extreme Voltage Shutdown (EVS) protection and Voltage and Current status readings.
Owner’s Manual ECM-15SH AC Power Conditioner & Suppression Module ECS-6RM Sequencer Controller Interface with ECM-15SH To get maximum use of the ECM-15SH we suggest using the ECS-6RM controller. When the two are interfaced the ECS-6RM controller not only can remotely turn on the ECM-15SH but it can monitor the AC Mains Voltage and Current of the ECM-15SH.
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual Wiring With an ECS-3 Sequencer Controller ECM-15SH DCV trigger- The ECS-3 can handle 15A of current before the breaker opens. If 15A is not enough current to support your power requirements you can use the 24VDC trigger to activate an additional power outlet such as the ECM-15SH. This triggered 24VDC voltage works in conjunction with Sequence 3 timing section. Contact Atlas Sound for AC outlet options.
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual Troubleshooting the ECM Module as a Standalone unit Note: All troubleshooting should be done by a certified electrician. Issue 1: Incoming AC LED is Not Illuminated. Possible Cause #1: Incoming AC mains circuit breaker has tripped due to excessive load. Action Needed: Check the AC outlet that the ECM is plugged into for 120V AC voltage.
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual Issue 3: Unit is set to External Trigger, the incoming AC LED is illuminated but the Active LED is not illuminated. Possible Cause #1: External DCV from the ECS-3 is not connected across the “+” and “G” terminals. Possible Cause #2: External DCV voltage polarity is not correct across the “+” and “G” terminals. Possible Cause #3: External DCV voltage is too low to activate the trigger circuit.
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual Issue 5: ECS-6RM Channel Activation Status LED is flashing and AC power at the ECM module is active. Possible Cause: The AC Mains Voltage at the ECM Module reached between 127- 132VAC or the voltage dropped between 107 101VAC. Action Needed: The ECS-6RM must be re-sequenced to turn off the LED, measure the AC mains before restarting the ECM Module.
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual ECM-15SH SPECIFICATIONS General Type Power Conditioner Suppressor Module Power Requirements 120V 60Hz Power Consumption .
Owner’s Manual ECM-15SH AC Power Conditioner & Suppression Module NOTES 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 – 15 – Specifications are subject to change without notice. AtlasSound.
ECM-15SH AC Power Conditioner & Suppression Module Owner’s Manual Limited Warranty All products manufactured by Atlas Sound are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any.