Owner`s manual

– 15 – AtlasSound.com
Specifications are subject to change without notice.
Owner’s Manual
DSP2210 &
DSP2212
Digital Processor
and Amplifier
1601 Jack McKay Blvd. Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 Fax: 800.765.3435
SYSTEM AMPLIFIERS (x2)
Frequency response 80Hz – 20kHz, ± 3dB
Total distortion .001% typical at +4dB, 1kHz, 0dB gain
Transformer output 70.7V
Efficiency 85% or better
Gain control adjustable to 34dB
Power supply UL / CUL recognized
Input impedance 50kΩ
Carrier frequency 400kHz
Peak current 1.2A
MTBF (Mean Time Between Failure) 100,000 hours
EMC / EMI radiation FCC Part 15 Class B, EN6100, CISPR 22
SYSTEM MECHANICAL DATA
Dimensions (L x W x H) 10.0" (254mm) x 19.0" (482.6mm) x 1.75" (44.45mm)
Material (outer housing) CRS (cold roll steel) 18AWG (.047" nominal)
Finish Flat black powder coat with zinc undercoat corrosion resistant
Printed circuit boards UL recognized UL94VO
Electronic components RoHS
Operating temperature to +50˚C
Storage temperature -40˚ to + 85˚C
Humidity 95% non-condensing (max.)
TROUBLESHOOTING GUIDE
1. Read and review all sections and follow instructions in this manual
2. Before terminating speakers to ‘Speaker Output (70V)’ Zones 1 and 2, verify that all wiring is free from shorts, opens, crosses,
ground problems or loose or frayed wiring. Ensure wiring follows the correct polarity (±) as shown in Section 4.2
3. Ensure AC power is correctly terminated with the IEC power cord provided. If after power is activated and system input and
output terminations are verified and no audio is detected, ensure all volume and activation settings have been properly set and
applied in the operating GUI / Sound Media Interface per instructions in Section 5.0 Ensure that all speakers are connected to
DSP2210/DSP2212.
4. If you continue to experience difficulty please contact Atlas Sound Customer Service department by telephone at 1-800-876-333,
online at www.AtlasSound.com, or by email at atlascusser@atlasound.com.