Front Panel
1. Unswitched AC Outlet
The120VACoutletisalwayslivewhentheAP-S20RTpowercordispluggedintoanACmainspowersourceandvoltageispresent.
Note: The AC mains power switch does not affect the Unswitched AC Outlet but it is protected with surge protection circuitry.
2. AC Mains Breaker
The 20A rated breaker will open if the combined draw of all AC outlets exceeds 20A. Note: The breaker is designed to exceed its rating
for a short period of time. If the breaker is tripped, you must first remove the load from the AP-S20RT and then push to reset.
3. Power Switch
ToturntheAP-S20RTOnorOff,presstheswitchtotheONorOFFposition.(SeerearpanelRemoteBypassSwitch)
4. USB Port 5VDC 1A
ConvenientUSBportforconnectingUSBracklightingorforchargingexternaldevicebatteries.Note: Will not charge all products. Some
devices require licensed charging circuitry.
5. Power ON Indicator
WillilluminateBluewhentheACMainsPowerSwitchisintheONPosition.
6. AC Fault Indicator
AlthoughtheClampingSuppressioncircuitvirtuallyassuresprotectionfrommosttransientvoltagespikesandsurges.Naturehasa
way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of damage.
Intherareinstancethatthisoccursandthecircuithasbeendamaged,theRed“ACFault”LEDindicatorwillilluminateandaninternal
buzzerwillsound.TheAP-S20RTwillshutoffpermanentlyuntiltheunitisrepaired.Beadvisedthatactivationofthisfaultconditionand
the associated repair is not covered under warranty. Note:IftheACFaultLEDisilluminated,itisimportanttohaveallequipmentthat
wasconnectedtothatACMainsLinebeinspectedforproperoperation.
7. EVS Protect Indicator
ThisLEDwillilluminatewhenanextremeoverorundervoltageconditionhasoccurred.Apowerlinevoltagebelow95VACorabove
140VACwilltriggertheEVScircuitry,removingpowerfromtheswitchedoutlets.Thisabnormalvoltageconditionmustbecorrected
before the AP-S20RT can be reset.