Installation Instructions

Sixth Course: Apply the 12” piece that was cut starting the 3rd course or cut 30” off the left edge of a shingle
and apply the remaining 12” piece over the fifth course, flush with the left edge and exposing the fifth course
6". Proceed with full shingle across roof maintaining 6" exposure. See Diagram #5.
Seventh Course: Apply the 6” piece that was cut starting the 2nd course or cut 36” off the left edge of a shingle
and apply the remaining 6” piece over the sixth course, flush with the left edge and exposing the sixth course
6". Proceed with full shingle across roof maintaining 6" exposure. See Diagram #5.
Course Completion: Begin eighth course application cycle, with full shingle (same as First Course method) and
continue with full shingle across roof. Continuation of this staggered course cycle must be followed to achieve
correct pattern appearance.
Note: Existing product manufactured with a 39 3/8” width (specified for installation at a 5” offset) can be
installed with the new 42” width size format (specified for installation at a 6” offset) as long as you follow the
“when mixing product” instructions.
WHEN MIXING PRODUCT: Always ensure the overlap between shingles is never less than 5” by checking
and measuring below and above the transition course. Check your seams to ensure it is never less than 5”, then
make the appropriate periodic cuts on your transition course.