User manual

2920 1461 03
29
User manual
14 Configuration menu
Function
To reprogram a number of parameters. See Figs. 3.1.
Procedure
1. Starting from the Main screen (see section 3.2):
- press the key Menu (F1)
- press the ¯ key until the option Modify params is
followed by a horizontal arrow
- press the tabulator key (5) to activate the menu
2. Use the ¯ key to scroll until the option Configuration is
followed by a horizontal arrow.
3. Press the tabulator key (5): The first option shown is Time.
If another option is desired, scroll through the display (using
¯ or keys) and select it using the tabulator key (5).
4. In case of option Time, the second line on the screen
indicates the actual setting, e.g. 14:30.
5. If it is desired to modify the time, press the key Mod. If
not, press the key Menu to return to the submenu.
6. After pressing the key Mod, the first field (14) will blink.
Modify the hours using the ¯ or keys. Then press the
tabulator key (5) to go to the next field (i.e. 30). The setting
of this field can now be modified with the ¯ or keys.
7. The bottom line of the display will show two options:
- Prog to program the new setting
- Canc to cancel the new setting
8. Proceed in a similar way for the other parameters to be
modified.
14.1 Programming compressor control
modes
Compressor control modes
The compressor can be controlled locally, remotely or via a
local area network (LAN). See the related Instruction book,
section 3.2.
Procedure
1. Starting from the Main screen (see section 3.2):
- press the key Menu (F1)
- press the ¯ key until the option Modify params is
followed by a horizontal arrow
- press the tabulator key (5) to activate the menu
2. Use the ¯ key to scroll until the option Configuration is
followed by a horizontal arrow.
3. Press the tabulator key (5): The first option shown is Time.
Scroll through the display (using ¯ or keys) until the option
CCM is followed by a horizontal arrow and select it using
the tabulator key (5). Following screen is shown:
CCM
Local control
Menu Mod ¯
F1 F2 F3
Fig. 14.1 Compressor control mode menu
4. Press the key Mod and use ¯ or keys to select the desired
control mode. Press the Prog key to program or the
Cancel key to cancel the modification.
15 Service menu
Function
- To reset the service plans which are carried out.
- To check for both the next service plans to be carried out
and to find which service plans were carried out previously.
Service plans
- Consult the related Instruction book to find which service
actions are related to these plans.
- Consult section 12 if any modification to the intervals should
be required.
When the service plan interval is reached, a message will appear
on the screen. See section 5.
Example
Programmed service plan intervals ex-factory
Service plans Intervals
Service plan A Each 4000 running hours
Service plan B Each 4000 running hours
Service plan C Each 8000 running hours
Service plan D Each 40000 running hours
Resulting service actions to be carried out
Service actions according to At
Service plan A and B 4000 running hours
Service plan A, B and C 8000 running hours
Service plan A and B 12000 running hours
Service plan A, B and C 16000 running hours
.