Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Controller
- 3.1 General
- 3.2 Control panel
- 3.3 Icons used
- 3.4 Main screen
- 3.5 Calling up menus
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Inputs menu
- 3.9 Outputs menu
- 3.10 Counters
- 3.11 Control mode selection
- 3.12 Service menu
- 3.13 Setpoint menu
- 3.14 Event history menu
- 3.15 General settings menu
- 3.16 Info menu
- 3.17 Week timer menu
- 3.18 Test menu
- 3.19 User password menu
- 3.20 Web server
- 3.21 Programmable settings
- 4 Installation guidelines
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Guidelines for inspection
- 11 PED (Pressure Equipment Directive)
- 12 Declaration of conformity
Compressor type I
tot
(1) Max
fuse (1)
I
tot
(2) Max
fuse (2)
Q21/Q2
2/Q23/
Q24
Q15
SF 17
+
UL/cUL 60 Hz 460 V 33 A 40 A 37 A 45 A 12.0 A 0.43 A
SF 17
+
UL/cUL 60 Hz 575 V 27 A 30 A 30 A 35 A 9.6 A 0.44 A
Compressor type I
tot
(1) Max
fuse (1)
I
tot
(2) Max
fuse (2)
Q21/Q2
2/Q23/
Q24
Q15
SF 22
+
IEC 50 Hz 230 V 85 A 100A 90 A 125 A 23.3 A 0.38 A
SF 22
+
IEC 60 Hz 380 V 53 A 63 A 57 A 63 A 14.5 A 0.26 A
SF 22
+
IEC 50 Hz 400 V 49 A 63 A 52 A 63 A 13.4 A 0.22 A
SF 22
+
IEC 50 Hz 400 V + N 49 A 63 A 58 A 63 A 13.4 A 0.22 A
SF 22
+
UL/cUL 60 Hz 200 V 101 A 125 A 109 A 125 A 25.0 A 0.74 A
SF 22
+
UL/cUL 60 Hz 230 V 88 A 110 A 94 A 125 A 24.0 A 0.26 A
SF 22
+
UL/cUL 60 Hz 460 V 44 A 60 A 48 A 60 A 12.0 A 0.43 A
SF 22
+
UL/cUL 60 Hz 575 V 35 A 40 A 38 A 40 A 9.6 A 0.44 A
Compressor type I
tot
(1) Max
fuse (1)
Q21/Q2
2
SFD 11
+
IEC 50 Hz 230 V 21 A 25 A 22.3 A
SFD 11
+
IEC 60 Hz 380 V 14 A 16 A 14.5 A
SFD 11
+
IEC 50 Hz 400 V 12 A 16 A 12.8 A
SFD 11
+
UL/cUL 60 Hz 200 V 26 A 30 A 21.9 A
SFD 11
+
UL/cUL 60 Hz 230 V 22 A 30 A 19.0 A
SFD 11
+
UL/cUL 60 Hz 460 V 11 A 15 A 9.5 A
SFD 11
+
UL/cUL 60 Hz 575 V 9 A 15 A 7.6 A
Compressor type I
tot
(1) Max
fuse (1)
Q21/Q2
2
SFD 15
+
IEC 50 Hz 230 V 28 A 32 A 15.0 A
SFD 15
+
IEC 60 Hz 380 V 17 A 20 A 8.9 A
SFD 15
+
IEC 50 Hz 400 V 16 A 20 A 8.7 A
SFD 15
+
UL/cUL 60 Hz 200 V 31 A 35A 13.7 A
SFD 15
+
UL/cUL 60 Hz 230 V 28 A 35 A 12.6 A
SFD 15
+
UL/cUL 60 Hz 460 V 14 A 20 A 6.3 A
SFD 15
+
UL/cUL 60 Hz 575 V 11 A 15 A 4.9 A
Compressor type I
tot
(1) Max
fuse (1)
Q21/Q2
2
SFD 22
+
IEC 50 Hz 230 V 41 A 50 A 22.3 A
Instruction book
2920 7140 52 97