Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Elektronikon Base Controller
- 3.1 ElektronikonTM Base Controller
- 3.2 Control panel
- 3.3 Icons used on the display
- 3.4 Main screen
- 3.5 Main function
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Service warning
- 3.9 Scrolling through all screens
- 3.10 Calling up running hours
- 3.11 Calling up motor starts
- 3.12 Calling up module hours
- 3.13 Calling up loading hours
- 3.14 Calling up load solenoid valve
- 3.15 Calling up/resetting the service timer
- 3.16 Calling up/modifying pressure band selection
- 3.17 Calling up/modifying pressure band settings
- 3.18 Calling up/modifying the unit of temperature
- 3.19 Calling up/modifying the unit of pressure
- 3.20 Calling up/modifying backlight time
- 3.21 Activating automatic restart after voltage failure
- 3.22 Keyboard lock
- 4 Installation
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Instructions for use
- 11 Guidelines for inspection
- 12 Pressure equipment directives
- 13 Declaration of conformity
Step Action
5 Regularly check the oil level. 10 to 15 minutes after stopping, the sight glass (SG)
should be between 1/4 and 3/4 full.
If the oil level is too low, stop the compressor, depressurise the oil system by
unscrewing oil filler plug (FC) one turn and wait a few minutes. Remove the plug and top
up the oil, until the sight glass is 3/4 full. Do not overfill. Fit and tighten plug (FC).
6 In automatic operation, the regulator is automatically controlling the compressor, i.e.
loading, unloading, stopping of the motors and restarting.
7 Regularly check the working pressure and the dew point (FF units).
8 Regularly check that condensate is drained (Da) during operation.
5.3 Stopping
Air outlet valve
Condensate drain valve on air receiver
Instruction book