Condensate drain valve on air receiver
Step Action
1 Consult the installation instructions (see Installation).
2 Check that the electrical connections correspond to the local codes. The installation
must be earthed and protected against short circuits by fuses in all phases. An isolating
switch must be installed near the compressor.
3 Fit outlet valve (2), close it and connect the air net to the valve.
Connect condensate drain valve (Dm) and automatic drain outlet (Da) to a drain
collector. Close the valve.
Connect condensate drain valve (4) of the air receiver to a drain collector. Close the
valve.
Oil system
Oil level sight-glass
Step Action
1 Check the oil level.
The oil level sight-glass (SG) should be between 1/4 and 3/4 full.