Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Elektronikon Base Controller
- 3.1 ElektronikonTM Base Controller
- 3.2 Control panel
- 3.3 Icons used on the display
- 3.4 Main screen
- 3.5 Main function
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Service warning
- 3.9 Scrolling through all screens
- 3.10 Calling up running hours
- 3.11 Calling up motor starts
- 3.12 Calling up module hours
- 3.13 Calling up loading hours
- 3.14 Calling up load solenoid valve
- 3.15 Calling up/resetting the service timer
- 3.16 Calling up/modifying pressure band selection
- 3.17 Calling up/modifying pressure band settings
- 3.18 Calling up/modifying the unit of temperature
- 3.19 Calling up/modifying the unit of pressure
- 3.20 Calling up/modifying backlight time
- 3.21 Activating automatic restart after voltage failure
- 3.22 Keyboard lock
- 4 Installation
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Instructions for use
- 11 Guidelines for inspection
- 12 Pressure equipment directives
- 13 Declaration of conformity
Fuses fuse rating
(V)
208 V 230 V 460 V Class
F1 600 V AC 2 A 2 A 1 A UL class JDYX or JDYX2 10.3 x 38mm
F4 (1)
2 fuses
600 V AC 15 A 15 A 6 A UL guide JDDZ class CC type FNQ-R 10.3 x 38
mm
(1): Fuse F4 only applicable to FF units. See also Electrical system for the service diagrams.
Motor terminal bridge configuration:
Factory standard connection is 230 V and can be changed to 208 V or 460 V.
Terminal bridges (1) can be removed using a pair of pliers.
Additional terminal bridges are provided with the compressor.
Voltage stickers:
Locate the yellow voltage labels provided with the compressor.
Replace the existing label with the appropriate voltage label (208 V, 230 V or 460 V).
Dryer terminal connection (X5):
Move wire connection to the desired voltage.
Dryer terminal X5
Instruction book