3.7 Shutdown
Description
The compressor will shutdown:
In case the temperature at the outlet of the compressor element exceeds the shutdown level (detected
by temperature sensor (TT11) or by temperature switch (TSHH11)).
In case of error of the outlet pressure sensor (PT20) or temperature sensor (TT11).
In case of overload of the compressor motor (M1)
Compressor element outlet temperature
If the outlet temperature of the compressor element exceeds the shutdown level (factory setting 115˚C/
239˚F):
The compressor will shutdown.
Alarm LED (5) will flash.
The following screen will appear:
Main screen with shutdown indication, element outlet temperature
The related pictograph
will appear flashing.
Scroll Up or Down buttons (4-8) until the current element outlet temperature appears.
Shutdown screen, element outlet temperature
The screen shows that the temperature at the outlet of the compressor element is 117 ˚C.