If one of the measurements exceeds the programmed shutdown warning level, this will also be indicated to
warn the operator before the shutdown level is reached.
Shutdown
If the compressor element outlet temperature exceeds the programmed shutdown level or the overload relay
of the main motor trips, the compressor will be stopped. This will be indicated on the display of the
controller.
Service warning
If the service timer exceeds the preset value, the controller advises the operator via the display, to carry out
the service maintenance.
Automatic restart after voltage failure
The controller has a built-in function to automatically restart the compressor when the voltage is restored
after voltage failure. This function is deactivated on compressors leaving the factory.
Instruction book
26 2920 7191 00