2.9 Air dryer
Air Dryer
Wet compressed air enters the dryer and is further cooled by the outgoing, dried air (2). Moisture in the
incoming air condenses. The air then flows through heat exchanger (1) where refrigerant evaporates,
withdrawing heat from the air. The cold air then flows through condensate trap (4) which separates
condensate from the air. The condensate is automatically drained. The cold, dried air then flows through
heat exchanger (3), where it is warmed up by the incoming air.