Brochure

6 - Atlas Copco G-series compressors Atlas Copco G-series compressors - 7
FULL FEATURE WITH BUILT-IN DRYER
The Full Feature version comes with a built-in
refrigerant air dryer. It cools the compressed air and
removes any moisture before it can enter your
compressed air network. This prevents rust in your
compressed air piping and avoids damage to your
air tools.
A CHOICE OF FILTERS
To ensure your compressed air meets the quality air
needs of a wide range of applications, different
grade PD/DD air filters can be selected.
QUALITY AIR PERFORMANCE
Untreated compressed air contains moisture, aerosols and dirt particles that
can damage your system and contaminate your end product. Atlas Copco’s
G-series compressors provide the clean, dry air that improves reliability,
avoids costly downtime and safeguards your products.
TYPICAL FLOW CHART FOR THE G 7-15 EL FF
2
A
B
C
3
4
5
6
9
10
11
12
13
14
15
16
17
7
8
1
AIR FLOW
1
Inlet air filter
2
Inlet valve
3
Compression element
4
Oil separator element
5
Minimum pressure valve
6
Aftercooler
7
Air receiver
OIL FLOW
8
Oil reservoir
9
Oil cooler
10
Thermostatic
valve block
11
Oil filter
OPTIONS
A
Full Feature
B
PD high efficiency air filter
C
Electronic receiver drain
REFRIGERANT FLOW
12
Evaporator
13
Refrigerant
compressor
14
Condenser
15
Capillary tube
16
Water separator
17
Electronic automatic
drain
TECHNICAL SPECIFICATIONS
Compressor
type
Maximum
working pressure
Capacity FAD
Installed
motor power
Noise
level
Weight
(kg/lbs)
*
bar(e)
psi l/s m
3
/h cfm kW hp dB(A) Pack
Full
Feature
50 Hz VERSION
GX 2 EP 10 145 4.0 14.4 8.5 2.2 3 61 165/364 200/441
GX 3 EP 10 145 5.3 19.1 11.2 3 4 61 165/364 200/441
GX 4 EP 10 145 7.8 28.1 16.5 4 5 62 165/364 200/441
GX 5 EP 10 145 10.0 36.0 21.2 5.5 7.5 64 165/364 200/441
GX 7 EP 10 145 14.0 50.4 29.7 7.5 10 66 214/472 264/582
G 7 EL 7.5 109 20.7 74.6 43.9 7.5 10 65 245/540 314/692
10 145 18.0 64.9 38.2 7.5 10 65 245/540 314/692
13 189 13.9 50.1 29.5 7.5 10 65 245/540 314/692
G 11 EL 7.5 109 28.7 103.3 60.8 11 15 67 257/567 326/719
10 145 24.0 86.5 50.9 11 15 67 257/567 326/719
13 189 19.2 69.1 40.7 11 15 67 257/567 326/719
G 15 EL 7.5 109 32.4 116.7 68.7 15 20 67 276/594 338/746
10 145 29.1 104.8 61.7 15 20 67 276/594 338/746
13 189 22.8 82.1 48.3 15 20 67 276/594 338/746
60 Hz VERSION
GX 2 EP 10.3 150 4.0 14.4 8.5 2.2 3 61 165/364 200/441
GX 4 EP 10.3 150 7.8 28.1 16.5 4 5 62 165/364 200/441
GX 5 EP 10.3 150 10.0 36.0 21.2 5.5 7.5 64 165/364 200/441
GX 7 EP 10.3 150 13.8 49.6 29.2 7.5 10 66 214/472 264/582
G 7 EL 7.4 107 21.2 76.3 44.9 7.5 10 67 245/540 314/692
9.1 132 18.7 67.3 39.6 7.5 10 67 245/540 314/692
10.8 157 16.4 59.1 34.8 7.5 10 67 245/540 314/692
12.5 181 13.8 49.8 29.3 7.5 10 67 245/540 314/692
G 11 EL 7.4 107 28.1 101.3 59.6 11 15 68 257/567 326/719
9.1 132 25.4 91.4 53.8 11 15 68 257/567 326/719
10.8 157 23.0 82.9 48.8 11 15 68 257/567 326/719
12.5 181 11.7 42.1 24.8 11 15 68 257/567 326/719
G 15 EL 7.4 107 33.1 119.3 70.2 15 20 68 276/594 338/746
9.1 132 29.6 106.7 62.8 15 20 68 276/594 338/746
10.8 157 27.3 98.4 57.9 15 20 68 276/594 338/746
12.5 181 23.1 83.3 49.0 15 20 68 276/594 338/746
*
Tank mounted variant.
EP: Electropneumatic, EL: BASE controller.
Standard air receiver size, GX 2-7 EP: 200 l/60 gal, G 7-15 EL: 270 l/80 gal.
Available options
GX 2-7
EP
GX 2-7
EP FF
G 7-15
EL
G 7-15
EL FF
Integrated aftercooler - -
O
Water separator (shipped loose) -
O
Timer water drain on water separator (shipped loose) - -
O
-
Timer drain on air receiver (tank mounted only)
O O O O
Electronic no loss water drain on water separator (shipped loose) -
O
Electronic no loss water drain on air receiver (500 l/120 gal tank mounted only)
O O O O
Integrated DD filter kit - - -
O
Integrated high performance PD filter kit -
O
-
O
500 l/120 gal air receiver (tank mounted only) - -
O O
Tropical thermostat - -
O O
OPTIONS
*
Length with inlet grating.
**
Dimensions of G 7-15 EL tank mounted are 1935 x 590 x 1463 mm (L x W x H)
with a 500 l vessel and 1880 x 590 x 1463 mm (L x W x H) with a 120 gal vessel.
L (mm) W (mm) H (mm)
PACK FLOOR MOUNTED
GX 2-7 EP 620 575/605
*
975
G 7-15 EL 810/840
*
590 1085
FULL FEATURE FLOOR MOUNTED
GX 2-7 EP - - -
G 7-15 EL 1205/1235
*
590 1085
PACK TANK MOUNTED
GX 2-7 EP 1420 575 1280
G 7-15 EL 1533 590 1332
FULL FEATURE TANK MOUNTED
GX 2-7 EP 1420 575 1280
G 7-15 EL 1533 590 1332
DIMENSIONS
Intake air
Air/oil mixture
Oil
Wet air
Dry air
Water
Refrigerant gas
Refrigerant liquid
W
H
L
H
WL
GX 2-7 EP
Floor Mounted
G 7-15 EL
Tank Mounted
Unit performance measured according to ISO 1217, latest edition.
Mean noise level (pack variant) measured according to Pneurop/Cagi PN8NTC2 test code; tolerance 3 dB(A).
Standard O Optional - Not available