Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Elektronikon Base Controller
- 3.1 ElektronikonTM Base Controller
- 3.2 Control panel
- 3.3 Icons used on the display
- 3.4 Main screen
- 3.5 Main function
- 3.6 Shutdown warning
- 3.7 Shutdown
- 3.8 Service warning
- 3.9 Scrolling through all screens
- 3.10 Calling up running hours
- 3.11 Calling up motor starts
- 3.12 Calling up module hours
- 3.13 Calling up loading hours
- 3.14 Calling up load solenoid valve
- 3.15 Calling up/resetting the service timer
- 3.16 Calling up/modifying pressure band selection
- 3.17 Calling up/modifying pressure band settings
- 3.18 Calling up/modifying the unit of temperature
- 3.19 Calling up/modifying the unit of pressure
- 3.20 Calling up/modifying backlight time
- 3.21 Activating automatic restart after voltage failure
- 3.22 Keyboard lock
- 4 Installation
- 5 Operating instructions
- 6 Maintenance
- 7 Adjustments and servicing procedures
- 8 Problem solving
- 9 Technical data
- 10 Instructions for use
- 11 Guidelines for inspection
- 12 Pressure equipment directives
- 13 Declaration of conformity
Location of oil filter and separator
Step Action
1 Run the compressor until warm. Stop the compressor, close the air outlet valve and
switch off the voltage. See Stopping.
2 Depressurise the compressor by unscrewing filler plug (2) one turn to permit any
pressure in the system to escape. Remove the plug after the system is depressurised.
3 Depressurise the air receiver by opening drain valve (8).
4 Remove plug (5), drain the oil by opening drain valve (6). Close the valve and refit the
plug after draining. Deliver the drained oil to the local oil collection service.
5 Remove oil filter (7) and separator (1). Clean the seats on the manifold.
6 Oil the gaskets of the new filter and separator and screw them into place. Tighten firmly
by hand.
7 Fill oil separator/tank (3) with oil until the level reaches the middle of sight-glass (4).
Ensure no dirt gets into the system.
8 Refit and tighten filler plug (2).
9 Close drain valve (8) of the air receiver.
10 Run the compressor for a few minutes.
11 Stop the compressor and wait a few minutes to allow the oil to settle.
12 If the oil level is too low, depressurise the system by unscrewing filler plug (2) one turn
to permit any pressure in the system to escape. Depressurise the air receiver by
opening drain valve (8).
13 Add oil as necessary. The sight-glass should be 3/4 full. Retighten plug (2) and close
drain valve (8) of the air receiver.
Instruction book
2920 7191 00 63