Carry out the service actions of the indicated plans or replace the component and reset the relevant timer, see
section Service menu.
Stopping
- Press stop button (9). Automatic operation LED (8) goes out and the compressor stops.
- To stop the compressor in the event of an emergency, press emergency stop button (10).
Alarm LED flashes (7).
•
Remedy the problem cause, unlock the button by pulling it out.
•
Navigate
to the Stop icon on the display by means of the navigation keys (3/4) and press the
Select key.
Press Reset.
Do not use emergency stop button (10) for normal stopping!
- Close the air outlet valve.
- Press the test button on top of the electronic water drain(s) to the depressurize the piping between
air receiver and outlet valve, next open the manual drain valve (Dm). See section Condensate
system.
Switch off the voltage.
Taking out of operation
- Disconnect the compressor from the mains.
- Unscrew the oil filler plug only one turn to permit any pressure in the system to escape.
- Shut off and depressurise the part of the air net which is connected to the outlet valve. Disconnect
the compressor air outlet pipe from the air net.
- Drain the oil.
- Drain the condensate circuit and disconnect the condensate piping from the condensate net.