Product Manual
Starting
Control panel Elektronikon® Graphic
Step Action
- Open the air outlet valve.
- Switch on the voltage. Check that voltage on LED (6) lights up.
- Press start button (1) on the control panel. The compressor starts running and the automatic
operation LED (8) lights up. Ten seconds after starting, the drive motor switches over from star
to delta and the compressor starts running loaded.
During operation
Keep the panels closed during operation.
When the motors are stopped and LED (8) (automatic operation) is alight, the motors may
start automatically.
When the automatic operation LED (8) is lit, the regulator is automatically controlling the
compressor, i.e. loading, unloading, stopping of the motors and restarting!
Regularly check the oil level during operation.
Instruction book
86 2920 7109 21