Product Sheet
S M A R T E R C L I M A T E L I V I N G
®
(Refers to diagram above)
A - 1897 mm
B - 1591 mm
C - 1300 mm
D - 300 mm
E - 591 mm
F - 674 mm
G - 800 mm
H - 800 mm
270 Litres
240 V
3.8
H 1897 x D 674 x W 591
90 Kg
37 dB(A)**
232605
Operating temperature range is from -5
o
C to 35
o
C
There is one inlet and one outlet connection of 160mm diameter at the top of the unit
for harvesting waste heat or ducting to the outside. Ducting further reduces sound levels.
• Electrical element 1,800 watt
• Rotary compressor
• Compressor outside of the tank
• Evacuation tube for condensation
• Steel glass lined tank
Ducting kit 160mm
Sound hood
Tank – 5 years. (6 year warranty when installed by accredited Atlantic plumber)
Heat Pump & Electrics – 2 year. (3 year warranty when installed by accredited Atlantic plumber)
Australia
T 61 (03) 9852 9599
E sales@atlantics.com.au
W www.atlantics.com.au
New Zealand
T 0800 422 000
E sales@atlantics.co.nz
W www.atlantics.co.nz
1880
1591
678
20
ø 580
1300
300
A
B
C
D
The Odysseo 2 has the same footprint as a standard electric storage heater. Since it
can be installed indoors, it is the ideal replacement for when a standard unit fails.
- 6 -
Installation
Selecting the location
Resistance of the floor
• Capable of withstanding a weight of at least 400 kg (the area under the water heater)
The place where the appliance is installed must comply with protection index IP X1B,
in compliance with IEC 529 Standard
Configuration without ducts
semi-ducted
Configuration with ducts
Type of room
• Unheated room at a temperature
above 5° and isolated from the
heated rooms in the dwelling
Recommended room = underground
or semi-underground, a room where
the temperature is higher than 10°C
all year long, well vented location
• Room at least above freezing
• Recommended room = habitable space
(the heat released by the water heater
is not lost), near the exterior walls
• Do not install near bedrooms to avoid
disturbance by the noise
Examples of rooms
• Garage, boiler room, basement,
laundry room, etc.
• Scullery, loft, cupboard in the hallway,
etc.
Volume of the room
from which the air is
taken
• > 20m3 • > 20m3
Temperature of the
room where the water
heater is installed
• 5°C to 35°C, when the water heater
is not working
• 1°C to 35°C
Temperature of the
incoming air
• 3°C to 35°C • -5°C to 35°C
Height
• > 2m10 • > 2m20 with bent outlet
(height of an insulated bend = approx.
300mm)
Required surface area
• (591+400) x 700 (l x D). See
diagram below
• The surface must be level
• (680) x 700 (l x D). See diagram below
• The surface must be level
Configuration without ducts Configuration without ducts
Configuration without ducts Configuration with ducts
CAUTION : failure to follow the recommendations for installation may result in poor system performance.
200 mm
700 mm
674 mm
990 mm
591 mm
674 mm
700 mm
990 mm
591 mm
700 mm
674 mm
680 mm
591 mm
F
E
G
H
*COP figure conforms to EN 255-3 for heating temperature between 15°C and 51°C. The ambient air is 20°C with relative humidity of 70%. Conforms to
Australian Standard AS/NZS 2712:2007 ** 37 dB measured at 2 metres.
SLA ATL/TAS 7/2012
Weight 90 Kg.
Can be horizontally transported.
Note: Control panel must be
in an upright position when
transported horizontally.
S M A RT E R C L I M AT E L I V I NG
®