Product Sheet
S M A R T E R C L I M A T E L I V I N G
®
The calculation of the dB level is exponential, which means that a sound
with a 10dB increase is twice as loud. By comparison, a whisper is
20dB, a quiet library is 30db, a typical refrigerator is 40dB and a regular
conversation is 50dB.
The compressor only draws 425 watts in normal working conditions. In
cold weather where the maximum output is required the draw is 750
watts. A standard electric element tank can use up to 3,000 watts.
The Odysseo is equipped with the patented
Atlantic Anti Corrosion Integral (ACI) technology. This advanced
technology provides maximum tank protection from corrosion and is
virtually maintenance free. Plus, the electric boost element is especially
adapted to all types of water.
The standard heating element operates at around 9 watts per square centimetre.
The Atlantic 1800-watt element has a larger surface area, a ceramic
structure and is rated at 4 watts per square centimetre. This means
scale build up is virtually eliminated in highly mineralized waters thus
maintaining efficiency.
Importantly, the element is mounted inside a sleeve, so the element can
be replaced without emptying the tank.
Most hot water systems are set at 60
o
C to prevent Legionella. A mixing
valve is then used to lower the water temperature for safety reasons.
To save considerable energy, yet provide maximum protection, the
Atlantic unit keeps the water temperature at 55
o
C then cycles once a
week to 60
o
C.
The unit can be operated on ECO heat pump only, Auto heat pump
priority with backup element or Boost heat pump and element.