User Guide

14
3
Failure diagnostic for use by professionals
4
The maintenance or repair work must be done exclusively by a professional.
TYPE OF FAILURE POSSIBLE CAUSE
DIAGNOSTIC AND REMEDY
No hot water
This water heater has a protection system
a
gainst dry heating: if the water heater is not
full of water, this protection system is activa-
ted and disables power supply to the heating
element.
Check if the water heater is full of water by
opening a hot water tap.
No heating
No hot water
No power supply to the water heater:
d
ay/night contact out of order…
Switch to forced operation and check if there is
any power on the power supply terminal of the
electronic thermostat.
H
eating element or its wiring out of order.
Check if there is any power on the connector of
the heating element, between blue and red wires.
Circuit of the impressed current anode (ICA)
i
s open:
its wires are wrongly connected or
out of order.
Bad position of the water heater (HM)
Heat sensor missing or wrongly connected.
V
isually check the connection of the impressed
current anode wires.
Check the position of the water heater and
p
lace it in the right position. Replace the sensor.
Check the presence and the right connection of
the sensor.
W
ater not war
m enough
Ther
mostat setting too low.
Turn the potentiometer (refer to the connection
label inside the cover).
Power supply time of the water heater insuf-
ficient: day/night contact out of order.
Check the good w
orking order of the day/night
contact.
Heating element or its wiring partially out of
order.
Check the 3 resistances of the heating element on
the connector of the element bundle and the
condition of the wire bundle.
Pilot light always off
Short-circuit on ICA wiring: no ICA protec-
tion.
Pilot light always off: contact the BIP Service.
First heating operation
At the f
ir
st star
t-up or after being switched off f
or a
long period (secondary residence) a few minutes
are needed before the light goes on.
In the case of an electricity power supply
for peak hours/off-peak hours: pilot light
off during peak hours
Stor
age batter
y out of order
Note: the storage battery is recyclable and
m
ust not be thro
wn a
wa
y.
Pilot light off when the water heater receiv
es no
power supply: replace the storage battery.
Other failures
Contact your import sailer for any other failure.
Ref
er to the last page of the man
ual f
or details.
ICA wir
ing
plastic base
heat sensor
ear
thing terminal
po
w
er supply cab
le
storage
battery
Pilot light
supply terminal (not polarized)
electronic thermostat
water temperature setting
heating element wiring
heating element wiring connector
heating element