User Guide

The connecting tubes must be sealed while installing the water heater (flax fibre, etc.), even if crosslinked
PE pipes are used.
A safety unit (not supplied with the water heater) in conformity with standard EN 1487 shall be screwed
onto the water heater cold water inlet.
When using pipes in synthetic materials (PER, etc), it is highly recommended to fit a thermoregulator at the
water heater outlet. It will be set according to the performance of the used material.
11
The pressure in the cold
water network is usually
less than 5 bars.
If it is not, provide a pres-
sure reducer that will be
located on the water
inlet after the meter.
C
ONNECTION DIAGRAM
EXAMPLE OF A VERTICAL WALL-MOUNTED WATER HEATER
This safety unit includes:
1 stop valve
1 manu
al drain valve
1 non-return valve (to prevent
water in the water heater from
flowing back into the cold
water network)
1 safety valve set to 7 bars
1 non-return valve inspection
plug
Hot water
outlet
Cold water
inlet
Siphon with funnel end
and air trap
Drain pipe
Pressure reducer if
P
> 5 bars on the
m
ain water inlet
Stop valve
Safety unit to be operated
t
wice/month
C
ast iron or steel coupling
or insulating fitting
IMPORTANT
3
ELECTRICAL CONNECTION
4
Our heaters are in conformity with standards in
force and consequently have all necessary safety
features. The electrical connection shall comply
with installation standard (France) NF C 15-100
and recommendations in force in the country in
which the water heater will be installed
(Certifying Label, etc.).
CONNECTION PROCEDURE
Unscrew the locking screw and remove the
protective cover, which contains the electrical
connection diagram.
The original connection f
or this water heater
is configured for 230 V~ single phase. For a 400
V~ three-phase connection you need to replace
the original single phase plate by a 400 V~ three-
phase kit (code 100000). Refer to the manual
enclosed with the kit for instructions for installa-
tion.
Connect the ends of the thermostat cables to
the screw terminals provided for this purpose
(there is no need to disassemble the thermo-
stat).
Connect the y
ellow/green earthing wire to
the terminal marked with the earthing symbol
on the door of the water heater.
Put the cover back after checking that the
connection terminals are correctly tightened.
If the temperature needs to be adjusted, refer
to the instructions inside the cover.
Put back and tighten the locking screw.
The electronic generator for water heaters with "impressed current anode" has been designed for a
permanent power supply or of the type operating in off-peak hours, 8 h or 6 h + 2 h.
Make sure that the installation respects one of these two power supply options,
the guarantee conditions will not be applicable for shorter off-peak times.
The installation shall include :
An omnipole circuit breaker with contacts
openings of at least 3 mm.
A power cable with rigid conductors with a
minimum cross-section of 3 x 2.5 mm in single
phase (phase, neutral, earth) or 4 x 2.5 mm in
three-phase (3 phases + earth).
The colour of the earthing conductor shall be
green/yellow.