F129 DESIGN Operating manual CMG-BD1 U0628726 ELECTRICAL CONVECTOR This product is only suitable for well insulated spaces or occasional use.
WARNING Caution, hot surface. WARNING: Some parts of this product may become very hot and cause burns on contact. Special care must be taken if children and vulnerable adults are present. - Children under 3 years must be kept away from this appliance, unless they are constantly supervised.
recycling. At the end of their life, products must be collected and recycled according to local regulations and ordinances. When an appliance is installed at a higher altitude, the air output temperature rises (around 10°C per 1000 m rise in ground). In case of use of the device in mobile version: Do not use it near a bath-tub, a shower or a swimming pool. Do not use this heating appliance near a bath, shower or swimming pool.
INSTALLATION Where to install the device? Zona 2 Zona 1 - This appliance has been designed to be installed in residential premises. Please consult your dealer if other circumstances apply. - It must be installed in accordance with professional standards, and comply with the regulations in force in the country of installation. - The appliances are class II and protected from water splashes to IP 24. They may therefore be installed in zone 2 of shower rooms. It is forbidden to install the device in zone 1.
For appliances equipped with absence detector: - To optimize the absence detection of your appliance, avoid installing the device in narrow corner or behind furniture. Do not install the appliance - In a draught that could affect its adjustment (beneath a centrally-controlled mechanical fan unit, etc.). - Underneath a fixed mains socket or near curtains or any other flammable materials. - The air outlet grid and control unit must be visible at the top of the appliance.
- The appliance must be placed on a horizontal surface. Please refer to feet kit assembly instruction on page 2 of this booklet or to instructions with feet (ref. 0517300, 0517400). Wall mounting version - Release the appliance’s latching bar. We recommend you place the appliance flat on the ground. Use a screwdriver to raise the tongue of the fitting, carefully so as not to distort it. While keeping the tongue raised, push the latching bar downwards to release the latches at the top.
- Lock the appliance onto latching bar. Place the appliance at an angle on the supports S1. Pivot the appliance to place it on the supports S2. Lower the appliance onto latching bar. The appliance clicks in place, showing it is fixed and latched. To release the appliance from the latching bar, use a flat-head screwdriver and push the tongue (top left of the latching bar behind the appliance) towards the wall. Lift the appliance while holding the tongue with the screwdriver.
OPERATING PRINCIPLE - Increasing and decreasing temperature (7°C to 30°C in Manual Mode only) without further mandatory confirmation - Navigation through the menu; - Confirmation; - Switching off; - Blocking, unlocking OPERATING MODES The appliance has 2 operating modes: Manual The appliance constantly maintains the temperature set in the settings. Prog The appliance runs an internal program configured for each day of the week.
- MANUAL mode will be activated. the set temperature will be 20°C. TURNING THE HEATING ON/OFF To turn the heating off, press and hold down . Confirm "OFF" command by pressing . To switch the appliance on, press and hold down . CONTROL LOCK To prevent changing the settings by children, you can lock the appliance controls by pressing and holding down . Select “Lock” and confirm by pressing . To unlock the controls, select “Unlock” . TEMPERATURE SETTING In MANUAL mode: MANUAL 20.
Menu in MANUAL mode Go to the Menu by pressing Mode To go back to main screen. The temperature can be set. Manual PROG Clock To set the date and time Off To switch the appliance off Back To go back to start screen Menu in PROG mode Go to the Menu by pressing Mode Manual To go back to main screen. Internal program is already preset.
Out of Comfort ranges, the setpoint temperature is ECO temperature, which can be adjusted in Temp.ECO section. Mode PROG Mode Program - Select the day using . Confirm . - Select using . Confirm . - Select the start time using or . Confirm . Select the end time using or . Confirm . How to copy the Program You can copy the program from a certain day to another day(s). - Select . Confirm . - Scroll through the days using or . - Select the day, to which the program is copied using .
Menu EXPERT To access the advanced features, press simultaneously and hold down and for at least 3 seconds. Menu General To adjust the setpoint temperature depending on the room temperature if a difference can be seen after 2 hours of heating. Calibration value in the interval between -3°C below and +3°C above the setpoint temperature. Example: if T° of the room = 18°C and the set T° = 20°C, select -2.0°. Sound To enable and disable key sounds Language To select the language Max.temp.
MODEL SPECIFICATIONS CMG-BD1 Specification Symbol Value Unit 0.5 - 2.5 0.0 2.5. kW kW kW 0.000 0.000 0.29 0.
ATTENTION! The housing protection should never be cleaned with abrasive and aggressive products. ADVICE FOR USERS Putting the appliance at its maximum setting will not increase the temperature faster. If you are out for several hours, consider lowering the temperature. If you have several appliances in one room, let them operate together, so you have a more uniform temperature while optimizing power consumption.
The benefits provided by this Warranty are in addition to all other rights and remedies in respect of the product which the consumer has under the competition and Consumer Act 2010. This guarantee excludes damage by neglect, shipping or accident and any damage due to incorrect installation, use or purposes other than those intended or failure to observe the instructions.
A Standards, quality labels B Commercial name C Commercial reference D Manufacturing reference E Serial number F Manufacturer number Type of Device Serial Number Name and address of the customer INSTALLER STAMP 17