Operating instructions
22 
How to release a jammed log? 
There is a risk of knotted logs getting stuck during the 
splitting process. 
1.  Switch machine off and disconnect the power. 
2.   Do not remove jammed logs with your hand
s. 
3.  Carefully move the stuck log with a crowbar backwards 
and forwards to loosen it. Don´t damage the splitting 
pillar. 
 Never hammer on the stuck log. 
 Never use a saw to cut the stuck log out of the machine. 
 Do not enlist the aid of a second person - this is a one- 
 man job. 
Finishing work: 
¾  Bring the splitting blade to the lower position (run-in 
state). 
¾  Release one of the control handles. 
¾  Switch the machine off and disconnect the power. 
¾  Follow the care and maintenance instructions. 
C
C
a
a
r
r
e
e
a
a
n
n
d
d
m
m
a
a
i
i
n
n
t
t
e
e
n
n
a
a
n
n
c
c
e
e
Remove the plug from the power socket before 
starting any maintenance or cleaning work. 
  Wear protective gloves in order to avoid injury to the 
hands. 
L Observe the following in order to keep the log splitter in 
good working order: 
  Clean the machine thoroughly after you have 
finished using it. 
  Remove any resin remains on the machine. 
  Lubricate the splitting column regularly or oil it using 
environmentally friendly spray oil. 
  Check the oil level and change the oil as necessary. 
  Check hydraulic hoses and hose connections 
regularly for any leaks and firm fitting. 
Sharpening the splitting blade 
After longer operating periods, for reduced splitting 
performance or slight deformation of the cutting edge, grind 
the splitting blade or sharpen it with a fine file (remove burrs). 
 How do I check the oil level? 
1.  The splitting column must 
 be in run-in state. Now 
 remove the dipstick. 
2.  Clean the dipstick and the 
 oil seal. 
3.  Replace the dipstick fully into 
 the oil reservoir. 
4.  Now remove the dipstick 
 again and read off the oil  
 level. 
  If the oil level is between the two marking on the 
dipstick, there is sufficient oil in the reservoir.
 If the oil level is below the lower marking, more oil should 
be added with the aid of a clean funnel. 
6.  Check the oil seal and replace it if it is damaged in any 
way. 
7.  Replace the dipstick into the oil reservoir. 
 When should I change the oil? 
The first oil change should be carried out after 50 
operating hours, and then every 500 operating hours. 
 Two persons are required for this. 
Changing the oil: 
1.  The splitting column must be in run-in state.  
2.  Now remove the dipstick. 
Oil dip 
stick 
Sharpen wedges 
upper marking 
lower marking 
dip stick 