User Guide
WebPAM User Manual
78
In the example above, amber ! icons appear over the Host, ATI, Controller,
Logical Drive View and Logical Drive icons. Click on the Logical Drive View or
Logical Drive icons to verify the condition of the logical drive.
In this example, the Status is Critical and Background activity is Idle. This
indicates that there is no automatic rebuild, so you must take action to restore the
logical drive:
1. Identify the failed disk drive.
2. Replace the failed disk drive.
3. Rebuild your logical drive.
Identify the Failed Disk Drive
Click on the Physical Drive View icon in the WebPAM user interface. Look for
a missing physical drive. A drive that used to be present but is suddenly absent is
the failed disk drive.
In this example, there were four disk drives connected to the ATI motherboard.
Notice that there is no drive on Port 3. This is the failed drive.
Replace the Failed Disk Drive
Replace the failed disk drive with a new one of equal or greater capacity. Then
rebuild the logical drive. See your system User Manual for more information
about replacing a disk drive.
Port 1
Port 2
Port 4
No drive
on Port 3