User guide
Appendix C Using the Optional Service Processor C-3
C.2.1 Using the util.exe Command Line Options
The util.exe can be invoked with a number of command line options. To run the
util.exe tool from the command line:
1. Insert the Sun Fire X2100 Server Supplemental CD into the Sun Fire X2100 Server
DVD drive and reboot the server.
2. When the Supplemental CD Main Menu displays, select the DOS Utility option.
3. Change to the latest IPMI subdirectory:
> cd flash\bios\latest\IPMI
4. Enter one of the util.exe commands at the prompt to set the appropriate value.
The command line options are listed in
TABLE C-1
Examples:
■ To set the IP address of the M3290: util.exe/ip=129.148.53.250
■ To load a new version of firmware: util.exe/rom=new.bin
See Section C.2.2, “Using the util.exe GUI” on page C-4 for information on
additional values to configure.
TABLE C-1
Command Function
util.exe/rom=filename Load the BMC firmware from filename
util.exe/c Clear all user passwords
util.exe/ip=x.x.x.x Set BMC IP address
util.exe/net=x.x.x.x Set BMC netmask
util.exe/? Help
util.exe/h Help