User guide

C-2 Sun Fire X2100 Server User Guide April 2007
After performing initial set up tasks with the util.exe utility, you can use IPMItool
v1.8.5 to monitor the following:
Sensors: Voltage, Temperature, Tachometers, Fan Speed Control, Chassis Intrusion
Control Command Set: Power up/down, System reset, System Power Cycle,
System NMI, Watchdog Timer
Diagnostic Command Set: Power-Good, CPU Voltage Identification, ACPI State
Detection, Request Message Redirection, Remote Console Redirection Over LAN
To use the IPMItool v1.8.5 client see, Section C.3.1, “Setting Up the SMDC Using
IPMItool” on page C-6.
The Sun N1 System Manager is a IPMI v1.5 client that is offered by Sun
Microsystems. For more information on the Sun N1 System Manager, see the
following URL:
http://www.sun.com/software/products/system_manager
C.2 Util. exe Utility
The util.exe utility is located on the Sun Fire X2100 Supplemental CD. Use this
utility for initial configuration of the SMDC. Before configuring the LAN values, you
will need to get the following information from your system administrator:
BMC IP address
BMC Netmask
BMC Gateway
You can use either a command line option or a GUI option for the SMDC
configuration.
Note The command line does not offer all the functions available in the GUI.
See the section for the option that you want to use:
Section C.2.1, “Using the util.exe Command Line Options” on page C-3
Section C.2.2, “Using the util.exe GUI” on page C-4