L1 Controller Error Messages
007-4701-003 127
Under certain circumstances a system software or hardware error can occur prior to the
graphics console's ability to display information. In this case you can see the error only
on the L1 controller panel or from an optional system console connected to the Console
serial port on the back of the system. In these cases an error message is displayed on the
L1 display of the form
<geoid> ERR <error code> or <geoid> POD <error code>. Most of the
time, these errors indicate a serious problem and customer service should be called
(please provide the error code to the service representative). See Table 5-3 for a partial list
of the L1 Hexadecimal boot error codes.
Table 5-3 L1 Controller Hexadecimal Boot Error Codes
Error code Message Meaning or Action Needed
0x80 The unit has no DIMM memory — insure that DIMM group 0 is fully populated. See
the information in “Removing and Replacing Memory DIMMs” on page 107.
0x81 Write to system controller timed out.
0x82 Request for system reset failed.
0x83 Local master arbitration failed.
0x84 No memory available to allocate hardware configuration structure.
0x85 Can’t initialize klconfig.
0x87 Disabled by environment variable.
0x88 Call to unimplemented chip specific function.
0x89 System controller communication initialization failed.
0x8b Nasid assignment failed
0x8c Route calculation failed.
0x8d Critical system controller transaction failed.
0xb0 PAL early self test failed.
0xb1 SAL entered with invalid function code.
0xb2 SAL invoked for firmware recovery.
0xb3 SAL_RESET called with bad parameters.
0xb4 main () returned
0xb5 PAL_CACHE_INFO failed looking for cache to reload.